Page 1
All manuals and user guides at all-guides.com Manuel FR-GB-ES Version 7.doc polytropic Français: p 3 English: p 19 Español: p 35 p:51...
Page 2
All manuals and user guides at all-guides.com Polytropic...
Page 3
All manuals and user guides at all-guides.com Polytropic...
Page 4
All manuals and user guides at all-guides.com Polytropic Sommaire Avertissement .......................... 5 Produit délivré et conditions générales d’utilisation............5 Personnes habilités......................... 6 Installation, maintenance, réparation ....................6 Utilisation, entretien: accessible à tous..................... 6 Normalisation........................... 6 Déclaration de conformité CE......................6 Installation électrique ........................
Page 5
La pompe à chaleur objet de ce manuel est uniquement destinée à réchauffer l'eau des piscines privées. Polytropic ne pourra être tenu pour responsable de toute autre utilisation. Le présent manuel d'instruction fait partie intégrante de la pompe à chaleur pour piscine qu'il désigne, il doit être lu avant toute utilisation de la pompe...
Page 6
être exercés par tout individu majeur ayant lu et compris les instructions de ce manuel. Normalisation Déclaration de conformité CE Les pompes à chaleur Polytropic sont conformes aux directives européennes suivantes : Compatibilité électromagnétique 89/336/CEE et modifications 92/31/CEE, 93/68/CEE, 93/97/CEE.
Page 7
All manuals and user guides at all-guides.com Polytropic Sécurité Bien que l'appareil soit conforme à toutes les exigences de sécurité, il présente des dangers résiduels : • Appareil sous tension électrique • Pièces en mouvement à mise en route automatique (ventilateur) •...
Page 8
All manuals and user guides at all-guides.com Polytropic Raccordement de l’eau Généralités La pompe à chaleur est raccordée au circuit de filtration avec un by-pass. Le by-pass doit impérativement être placé après la pompe et le filtre. Le by-pass est constitué par 3 vannes.
Page 9
Valeurs indicatives : Protection Pompe à Régime Câblage* tête de chaleur ligne PAC 16 monophasé 3 x 2,5mm² 20 A PAC 22 monophasé 3 x 4mm² 25 A 16 A x 3 ou PAC 31 triphasé...
Page 10
5 x 400 V 3 x 16 A 15 m 27 m 39 m 57 m 96 m (18 kW) PAC 16 3 x 230 V 20 A 21 m 33 m 48 m 81 m (8 kW) PAC 22...
Page 11
All manuals and user guides at all-guides.com Polytropic Utilisation Instructions accessibles à tous Mise en eau Schéma du by-pass Attention, le by-pass doit impérativement être placé avec une fixation au mur ou un support de maintien, afin que le poids du by-pass et des tubes ne soit pas uniquement supporté...
Page 12
All manuals and user guides at all-guides.com Polytropic Vous pouvez alors mettre votre machine en marche, pour cela, veillez à bien suivre les points suivants dans l’ordre pour chaque mise en route de la machine en début de saison): •...
Page 13
All manuals and user guides at all-guides.com Polytropic La plage de fonctionnement des machines est comprise entre 10° C et 35° C d’air ambiant. Quand le compresseur est arrêté, la temporisation avant sa mise en marche est de deux minutes.
Page 14
All manuals and user guides at all-guides.com Polytropic Fréquence du réglage Le débit à faire passer dans la pompe à chaleur dépend beaucoup de la température d'eau et dans une moindre mesure de la température de l'air. Il convient donc de le régler : •...
Page 15
All manuals and user guides at all-guides.com Polytropic Ne jamais faire l'injection de produits chimiques (chlore, acide, etc.) directement dans le panier filtre de la pompe ! Il s'amorcerait alors d'une décharge hautement corrosive qui pourrait endommager l'échangeur de chaleur, et causer la perte totale de la pompe à...
Page 16
Déclaration de conformité Déclaration de conformité Déclaration de conformité Les pompes à chaleur Polytropic sont conformes aux dispositions : • Compatibilité électromagnétique 89/336/CEE • Basse tension 73/23/CEE En fin de vie de l’appareil, celui-ci doit impérativement être confié à un professionnel compétent (frigoriste) afin de procéder à...
Page 17
Polytropic Installateur Instructions destinées aux professionnels Instructions complémentaires Pressostat Les pompes à chaleur Polytropic sont équipées d'un pressostat de sécurité HP, celui-ci est un pressostat normalement ouvert calibré en usine à 30 Bar. Implantation Aspiration d’air : Sortie d’eau Entrée d’eau...
Page 18
La charge de gaz n’est machine sous pression requiert l’intervention de ne fonctionne pas pas correcte (micro fuite (entre 5 et 10 bars a Polytropic ou d’un ou s’arrête au bout ou autre) l’arrêt selon la frigoriste. de quelques température extérieure) minutes Vérifier avec le logiciel...
Page 19
All manuals and user guides at all-guides.com Polytropic...
Page 20
All manuals and user guides at all-guides.com Polytropic Synopsis Warning ..........................21 Product delivery and general conditions of use ..............21 Qualified Personnel ....................... 22 Installation, handling, repairing ....................... 22 Use, maintenance: competent persons ..................22 Standards ..........................22 CE standard conformity ........................
Page 21
The pool heat pump referred to in this handbook is designed and built solely for private swimming pool use. Polytropic can not be held responsible for any other use. This handbook is considered as a part of the pool heat pump. It must be read and adhered to before installation and use of appliance.
Page 22
If you are unsure, always call a qualified engineer. Standards CE standard conformity Polytropic heat pumps conform to the following standards: European electromagnetic standard: 89/336/CEE and modified: 92/31/CEE, 93/68/CEE, 93/97/CEE. European low power standard: 73/23/CEE and French standard: NF EN 60335-1, NF EN 60335-2-40.
Page 23
All manuals and user guides at all-guides.com Polytropic Safety Although this product conforms to all the requirements of safety, it may still present residual dangers: • Electrically controlled parts • Parts moving with automatic start-up (fan) • Cutting edges (evaporator)
Page 24
All manuals and user guides at all-guides.com Polytropic Water connection Generalities The heat pump is connected to a filtration circuit with a by-pass. It is imperative that the by-pass is placed after the pump and the filter. The by-pass generally consists of 3 valves.
Page 25
Informational values: Head of power Maximum input Heat pump Regime Cable size supply line amperage protection PAC 16 monophasis 3 x 2.5mm²* PAC 22 monophasis 3 x 4mm²* 16A x 3 or PAC 31 triphasis 5 x 2.5mm²* 16A triphasis...
Page 26
5 x 400 V 3 x 16 A 15 m 27 m 39 m 57 m 96 m (18 kW) PAC 16 3 x 230 V 20 A 21 m 33 m 48 m 81 m (8 kW) PAC 22...
Page 27
All manuals and user guides at all-guides.com Polytropic Utilisation User instructions Water connection By-pass diagram Warning, the by-pass must be fixed on a wall or on a support, so that by- pass and tubes weight is not supported by the heat pump connexions!
Page 28
All manuals and user guides at all-guides.com Polytropic You can then start your machine. (Follow every point in the below order each time you start the pool heat pump, especially at the beginning of a season): • Open by-pass valves •...
Page 29
All manuals and user guides at all-guides.com Polytropic Water flow setting To optimize the performance of heating and energy saving, it is advisable to regulate the water flow through the pool heat pump. The adjustment must be carried out according to the indication given by the setting gauge.
Page 30
All manuals and user guides at all-guides.com Polytropic Then, normally, the flow doesn't need to be regulated further. It is simply enough to check pressure value on pressure gauge to ensure that the pool heat pump is working normally and that the flow hasn't changed.
Page 31
All manuals and user guides at all-guides.com Polytropic • Turn pool heat pump on, set temperature, set water flow. • Cover the pool with solar cover. Leave pool system and pool heat pump working permanently until pool is at the required temperature (approximately 36 hours to 1 week with a normal size unit).
Page 32
Conformity declaration Conformity declaration Conformity declaration Conformity declaration Polytropic pool heat pumps are standards to: • Electromagnetic compatibility 89/336/CEE • Tension low 73/23/CEE At the end of product lifetime, this one must imperatively be entrusted to a qualified professional (refrigeration technician) in order to dismantle it in accordance with the laws in force (recovery of gas cooling, of metallic materials which can be recycled...)
Page 33
All manuals and user guides at all-guides.com Polytropic Specialist Qualified personnel instruction Complementary instructions Internal pressure controller Polytropic heat pumps have an internal security pressure controller set to 30bars. Installation Inlet air flow: Water outlet Water inlet Outlet air flow: Defects diagnostic After a correct installation and connection, your Polytropic heat pump doesn’t...
Page 34
Problem of gas charge between 5 and 10 bars Contact your seller few minutes after when heat pump is starting stopped Check with Polytropic This heat pump don’t fit software Contact your seller well to your pool www.polytropic.fr Heat pump works “aquavariation”...
Page 35
All manuals and user guides at all-guides.com Polytropic...
Page 36
All manuals and user guides at all-guides.com Polytropic Índice Advertencia ..........................37 Producto expedido y condiciones generales de utilización ..........37 Personal habilitado........................ 38 Instalación, mantenimiento, reparación: Profesional Obligatorio ............ 38 Utilización, mantenimiento: accesible para todos ................38 Normativas ..........................38 Declaración de conformidad CE .....................
Page 37
Solicitamos a los clientes que utilicen la bomba de calor para piscina Polytropic de conservar el embalaje de la misma (cartón + poliestireno + paleta) durante todo el periodo de garantía, a fin de evitar problemas de deterioro en el caso de que la máquina debe de retroceder vía transporte.
Page 38
Puede realizarlo una persona particular, siempre y cuando haya leído y comprendido con exactitud este manual de instrucciones. Normativas Declaración de conformidad CE Las bombas de calor Polytropic son conformes a las directivas europeas siguientes: Compatibilidad electromagnética 89/336/CEE y modificaciones 92/31/CEE, 93/68/CEE, 93/97/CEE.
Page 39
All manuals and user guides at all-guides.com Polytropic Seguridad Dado que la maquina debe estar conforme con todas las exigencias de seguridad, puede presentar algunos peligros puntuales: • Aparato bajo tensión eléctrica • Piezas en movimiento a la puesta en marcha automática (ventilador) •...
Page 40
All manuals and user guides at all-guides.com Polytropic Conexiones de agua General La bomba de calor es conectada al circuito de filtración con un by-pass. El by-pass debe imperativamente estar colocado después de la bomba y el filtro. El by-pass está generalmente constituido por 3 válvulas.
Page 41
Las conexiones deben de estar dimensionadas en función de la potencia del aparato y del estado de la instalación. Protección de Bomba de calor Régimen Cable* la alimentación PAC 16 monofásico 3 x 2,5mm² 20 A PAC 22 monofásico 3 x 4mm²...
Page 42
5 x 400 V 3 x 16 A 15 m 27 m 39 m 57 m 96 m (18 kW) PAC 16 3 x 230 V 20 A 21 m 33 m 48 m 81 m (8 kW) PAC 22...
Page 43
All manuals and user guides at all-guides.com Polytropic Utilización Instrucción accesible para todos Puesta en agua Esquema de By-pass ¡Atención, se debe fijar el by-pass a un soporte mural o de suelo para que su peso lleno de agua no venga estropear las conexiones de la bomba de calor! Una vez que el aparato esté...
Page 44
All manuals and user guides at all-guides.com Polytropic • Las condiciones de instalación descritas deben de ser respetadas. Puede usted poner en marcha su maquina, para ello seguir bien el orden para cada puesta en marcha que vaya a realizar: •...
Page 45
All manuals and user guides at all-guides.com Polytropic Los Bombas de Calor Pac 16 hasta pac 31 están diseñados a operar en temperaturas ambientales entre 8° C y 35° C. Si se para el compresor tarda dos minutos hasta el compresor arranca de nuevo.
Page 46
All manuals and user guides at all-guides.com Polytropic • En marcha el servicio la bomba de calor y que el agua sea fría • Una vez pendiente de la fase de subida de la temperatura • Cuando la temperatura deseada es afectada.
Page 47
All manuals and user guides at all-guides.com Polytropic • La subida de temperatura al principio de la estación • El mantenimiento de la temperatura durante la estación Subida de temperatura Cuando esté interesado en utilizar su piscina al principio de la estación, debe de aislar su bomba de calor del circuito de filtración:...
Page 48
Declaración de conformidad Declaración de conformidad Declaración de conformidad Declaración de conformidad Las bombas de calor Polytropic son conformes a: • Compatibilidad electromagnética 89/336/CEE • Base tensión 73/23/CEE Al final del ciclo de vida del producto es absolutamente necesario que la maquina se entrega a un profesional (técnico de refrigeración) para el deshecho...
Page 49
Polytropic Instalador Instrucciones destinadas a los profesionales Instrucciones complementarias Presostato Las bombas de calor Polytropic están equipadas de un presostato de seguridad HP, éste presostato, normalmente abierto calibrado desde fábrica a 30 Bar. Implantación Aspiración de aire: Salida de agua...
Page 50
Instalar un toldo de se pierden por el sobre la piscina? burbuja evaporador Si usted está delante de un posible problema que no estuviera en este cuadro de soluciones, os invitamos a contactar con nuestro servicio SAT de Polytropic lo más rápidamente posible...
Page 51
All manuals and user guides at all-guides.com Polytropic Caractéristiques / Characteristics / Características Dimensions / Dimensiones PAC16 Small & PAC22 Medium...
Page 52
All manuals and user guides at all-guides.com Polytropic PAC31 Large...
Page 53
All manuals and user guides at all-guides.com Polytropic Schémas électriques / Wiring diagrams / Esquemas eléctricos PAC16 Small & PAC22 Medium...
Page 54
All manuals and user guides at all-guides.com Polytropic PAC31 Large...
Page 55
Este documento debe de Please detach this sheet and Cette feuille est ensuite à enviarse lo más rápidamente return it to Polytropic by fax or détacher et renvoyer ou faxer posible a Polytropic a la post mail. à Polytropic.
Page 56
All manuals and user guides at all-guides.com Polytropic...