5. Clean the recess and motor shaft thoroughly.
6. Install the new seal assembly.
a. Insert the silicon carbide seal and the rubber gasket into the recess of the Seal plate.
NOTE: To help facilitate installation, apply a drop of liquid soap to the outside diameter of the rubber gasket. Make
certain that the polished surface of mechanical seal and motor shaft are kept clean and free of dirt and/or oil.
b. Slip the remaining parts of the rotary seal assembly onto the motor shaft.
NOTE: Apply a drop of liquid soap to the inside diameter of the rubber drive ring.
7. Replace the impeller and diffuser removed in Steps 2 & 3.
8. Reassemble the pump body to the motor and mounting bracket.
16
ITEM
DESCRIPTION
1
Motor
2
Seal Plate
3
O -ring
4
Mechanical Seal Assembled,E-5/8"
5
Impeller
6
Diffuser
7
Diffuser Ring
8
Control Valve Body
9
Flow Control Screw
10
Pressure Switch
Plug 1/8" NPT
11
12
Pump Body
13
Pressure Gauge
14
Lead Wire
15
Mounting Ring
16
Base
17
Rear cover
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1