Telephone Helpline: 0845 146 2887 (United Kingdom)
Troubleshooting
Fault
The unit is not
working
Rice is not thoroughly
cooked
Rice is overcooked
Technical Specifications
Model
Voltage
CN324
230V 50Hz
J300
230V 50Hz
CB944
230V 50Hz
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The bowl is not in contact with the
heating plate
The bowl is not in contact with the
heating plate
The bowl has become deformed
Not enough water
Too much water
Power
Current
1550W
6.8A
1950W
8.5A
2950W
12.8A
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Realign bowl
Reposition bowl
Replace bowl
Increase the amount of water used
Decrease the amount of water used
Capacity
Weight
4.2 litres
5.5kg
6 litres
10.2kg
23 litres
11.8kg
UK
Action
Dimensions
h x w x d mm
350 x 380 x 320
335 x 420 x 420
555 x 485 x 395
4