8 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
8.1
Cleaning
Under normal conditions, the water pump is free of maintenance. However, the pump should
not be placed in the open air during rain, in a humid place, or dirty or frozen environment.
Freezing, idling or blocking by impurities should be avoided.
Always disconnect the power supply before maintenance of the pump.
If the power cable is damaged, it must be replaced by professional personnel. Damage
caused by short circuiting is not included in scope of the guarantee.
If trouble with the pump is experienced, guaranteed repairs must be carried out by an
authorized maintenance center.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
9 TECHNICAL DATA
type
Mains voltage / frequency
Rated power
Max. pump capacity
Max. lift
Maximum suction level
Max. water temperature
Min. diameter of suction hose
Min. diameter of pressure hose
Cable length
10 NOISE
Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
Acoustic power level LwA
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
11 TROUBLE SHOOTING
PROBLEM
The electric motor is
running but the pump
does not suck water
Copyright © 2022 VARO NV
POWXG9554
POSSIBLE CAUSE
After the pump
starts, the pump
body does not fill
with water
P a g e
POWXG9554
230V~ /50Hz
1000W
3500 l/hour
44 m
7 m
35°C
1" (25mm)
3/4" (20mm)
1,2 m
72 dB(A)
86 dB(A)
SOLUTION
Fill the pump with water
| 5
EN
www.varo.com

Publicité