INSTALLATION
protection must extend under and 2" (51 mm) to each side
of the chimney tee for an interior vertical installation.
Canada: Require a minimum of 475 mm [18"] beyond the
front of the unit and 203 mm [8"] beyond each side of the
unit. A Floor Protector of 1/4 inch thick is recommended
for this installation.
A
B
Floor Protector
Floor Protector
A
Rear
B
Side
C
Front
D
Rear
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home, and alcove applications in
accordance with the clearances given in this manual.
For safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in clearance to
combustibles may only be done by means approved by a
regulatory authority.
B
C
D
1"
25 mm
USA
6"
153 mm
CAN
8"
203 mm
USA
6"
153 mm
CAN 18" 475 mm
2"
50 mm
E
H
TABLE 1 CLEARANCES
E Back wall to unit
PARALLEL
F Sidewall to flue
G Sidewall to top edge of unit
CORNER
H Adjacent wall to unit
OUTSIDE AIR SUPPLY
IN A MOBILE HOME)
DO NOT VENT UNDER ANY PORCH, DECK, AWNING,
OR IN ANY SEMI ENCLOSED OR ROOFED AREA. DOING
SO MAY RESULT IN UNPREDICTABLE AIRFLOW AT THE
VENT CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE, AS
WELL AS, OTHER UNFORESEEABLE ISSUES.
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside air
intake (69FAK) which is necessary for a mobile home.
You can purchase the 69FAK through your heater dealer.
Installation instructions are supplied with the air intake kit.
5
© 2021 United States Stove Company
E
F
G
H
H
(OPTIONAL, UNLESS INSTALLING
ATTENTION:
F
G
H
in
mm
3
76
11
280
8
203
8
203