Altrad Lescha SPL Serie Notice Originale page 28

Publicité

Model / Type
Year of construction
Splitting force
Log length
Log diameter
Stroke
Feed speed
Return speed
Hydraulic oil (max.)
Hydraulic pressure
Electric motor performance (power consumption)
Power supply
Dimensions
Weight
Before each fault clearance:
− switch off device
− pull out main plug
Problem
Logs are not being split
properly
(insufficient splitting
performance).
Splitting
column
moves
unsteadily or with strong
vibrations.
Splitting column does not
move in.
Motor will not start.
In case of further faults or inquiries please contact your local dealer.
Please observe the enclosed terms of guarantee.
28
T
T
P
o
P
o
Possible cause
⇒ The log is not positioned correctly.
⇒ The log exceeds the maximum dimensions or
the wood is too hard for the performance of
the machine.
⇒ Splitting blade does not split log.
⇒ Hydraulic pressure too low.
⇒ Release rods bent (hydraulic tappet not quite
pressed in).
⇒ Incorrect connecting lead (longer than 10 m or
too small cable cross-section).
⇒ Air in the circuit.
⇒ Splitting column not sufficiently lubricated or
oiled.
⇒ Hydraulic pump defective.
⇒ No electrical power.
⇒ Connection cable defective.
⇒ Electric motor defective.
e
c
h
n
i
c
a
l
d
a
t
a
e
c
h
n
i
c
a
l
d
a
t
a
min. 120 mm – max. 340 mm
P
3.5 kW S6 (4 min/6min)
1
230 V ~ 50 Hz, 16 A time-lag
length 760 x width 500 x height 1520 mm
s
s
i
b
l
e
p
r
o
b
l
e
m
s
s
s
i
b
l
e
p
r
o
b
l
e
m
s
Remedy
⇒ Reposition the log correctly.
⇒ Cut
⇒ Sharpen splitting blade, check for burrs or notches.
⇒ Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ Arrange for manufacturer or authorised company to
adjust the rods.
⇒ Use the correct connecting lead.
⇒ Check the oil level and add more oil if necessary.
⇒ Lubricate splitting column or oil with environmentally
friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ To correct the problem, refer to the manufacturer or
other approved service centre.
⇒ Check the fuse.
⇒ Replace the connection cable or have it checked by an
electrician.
⇒ To correct the problem, refer to the manufacturer or
other approved service centre.
G
u
a
r
a
n
t
e
e
G
u
a
r
a
n
t
e
e
SPL 6
see last page
60 kN (6 t)
max. 1050 mm
≈ 500 mm
approx. 0.04 m/sek.
approx. 0.17 m/sek.
4.5 litres
21 MPa (210 bar)
approx. 100 kg
the
log
to
the
required
dimensions.