XR60C/XR06C
XR60C
XR06
code
code
Set
Set
Main Set point, Freezer
Set
Set
Main Set point, Glas Froster
Hy
Hy
Differential ( hysteresis )
LS
LS
lower limit of main set point
US
US
Upper limit of main set point
Ot
Ot
Offset
P2P
P2
Evaporator probe presence
OE
OE
Evaporator probe calibration
OdS
Od
Outputs delay at start up
AC
AC
Minimum time interval between the disactivation and successive activation on compressor
COn
Cy
Compressor on-time during probe failure
COF
Cn
Compressor off-time during by probe failure
CH
CH
Kind of action, Cool/Heat
CF
CF
Unit of measure
rES
rE
Resolution
Lod
Ld
Probe displayed
Dy
Display delay
tdF
Td
Defrost type
dtE
dE
Defrost –end temperature
IdF
Id
Time interval between defrost cycle
MdF
nd
Max defrost cycle time
dSd
Dd
Start defrost delay
dFd
dF
Displaying during defrost
Fdt
Dt
Dripping time
dPo
dP
First defrost cycle after controller startup
Fnc
Fc
Fan operating mode during normal controller
Fnd
Fd
Fan activation delay at controller startup and after defrost
FSt
FS
Fan stop temperature
ALU
AU
Max temperature alarm
ALL
AL
Min temperature alarm
ALd
Ad
Maximum or minimum temperature alarm delay
AdA
dA
Exclusion of temperature alarm at startup
dAd
Real temperature display delay at defrost end
IP
IP
Digital input polarity
IF
IF
Digital input configuration
dI
dI
Digital input delay
dC
dC
Status for door open fubction
Rd
Rd
Regulation with door open
Freezer/Glass Froster
PARAMETER
-22 °C
-14 °C
6 °C
-24 °C
-10 °C
10 °C
Y
0 °C
3 min
5 min
15 min
30 min
C
°C
in
P1
5 min
in
6 °C
4 hour
30 min
0 min
SEt
3 min
n
on
5 min
-6 °C
99 °C
-55 °C
99
90 min
30 min
Cl
Au
99 min
FC
y
36