Télécharger Imprimer la page

Robby VEN550W Mode D'emploi page 14

Publicité

Danger of physical injury and death!
Improperly conducted repairs may prevent your appliance from working safely.
Such repairs will endanger you and your surroundings.
Minor faults are often sufficient to cause a malfunction. In most cases, you will be able to
correct these faults easily yourself. Please start by referring to the following table before
contacting our technical support. This will help you save much effort and possibly expense.
Fault/malfunction
Pas de tension secteur ?
Surchauffe du moteur due à :
Pump does not run
• température liquide est-elle
haute ?
• bloquer par des corps étrangers ?
Déclenchement du disjoncteur de courant résiduel
(RCCB) ?
Moteur défectueux ?
Les ouvertures d'aspiration sont-elles bloquées ?
Pump runs but does
La pompe aspire-t-elle de l'air ?
not pump.
Pompe bloquée par des corps étrangers ?
Delivery height too great?
Pressure line diameter too small?
Delivery rate too
Pressure line blocked?
low.
Suction openings blocked?
Pressure line kinked?
Pressure line leaks?
Pump runs very
Pump draws in air?
loud- ly..
If you are unable to correct a fault yourself, please contact our technical support directly.
Please note that improperly conducted repairs will void your warranty and may cause you
additional expenses.
Technicals data
Cause
Imported by / Importé par ROBBY - 225 avenue de Coulins - 13420 Gémenos
Vérifier les câbles, la fiche, la prise et le fusible.
Eliminate the cause of the overheating (max. temperature of liquid
► Technical data – p. 8 )
Activate RCCB. Contact qualified electrician if RCCB triggers again.
Contact service partner.
Rectify blockage.
- Keep the pump at an angle while sub- merging.
- Switch the pump on and off several times in order to expel air.
Clean the pump (► Cleaning the suc- tion area – p. 6 )
Comply with maximum delivery height (► Technical data – p. 8 ).
Use pressure line with larger diameter.
Rectify blockage.
Clean suction opening.
Straighten pressure line.
Seal pressure line, tighten threaded connections.
- Ensure there is sufficient liquid present.
- Keep the pump at an angle while sub- merging.
Remedy
14

Publicité

loading

Ce manuel est également adapté pour:

Vp550w