ITALIANO
General precautions for installers
Read the instructions carefully before beginning the installation and carry out the procedures as
specifi ed by the manufacturer. • Installation, programming, commissioning and maintenance must
only be carried out by qualifi ed, expert technicians and in full compliance with the applicable law.
• Only use this product for its intended purpose. Any other use is hazardous. • The manufacturer
cannot be held liable for any damage caused by improper, unreasonable or erroneous use. • Also
check the warnings in the installation and use manuals for the operator the product is associated
with. • Make sure the mains power supply is disconnected during all installation procedures. •
This product complies with the applicable standards in force at the time of manufacturing. • The
product, in its original packaging supplied by the manufacturer, must only be transported in a
closed environment (railway carriage, containers, closed vehicles). • If the product malfunctions,
stop using it and contact customer services at https://www.came.com/global/en/contact-us or via
the telephone number on the website. • The manufacture date is provided in the production batch
printed on the product label. If necessary, contact us at https://www.came.com/global/en/contact-
us. • The general conditions of sale are given in the offi cial CAME price lists.
If the device is not powered by a CAME control panel, make sure that the supply
voltage to the device features a current limiter of not greater than 1.5 A.
Legislative references
This product complies with the applicable standards in force at the time of manufacturing. • CAME
S.p.A. declares that the product described in this manual complies with Directive 2014/53/EU and
the Radio Equipment Regulations 2017. • The full EC declaration of conformity and UK Conformity
Assessed (UKCA) marking information can be found at www.came.com.
Dismantling and disposal
Dispose of the packaging and the device responsibly at the end of its life cycle, in compliance
with the laws in force in the country where the product is used. The recyclable components are
marked with the material symbol and ID. • THE DATA AND INFORMATION IN THIS MANUAL MAY BE
CHANGED AT ANY TIME AND WITHOUT NOTICE. • MEASUREMENTS ARE IN MILLIMETRES, UNLESS
STATED OTHERWISE.
Description
806SL-0080
SELD2BDG - BUS CXN recess-mounted key selector with blue backlighting and DIN lock cylinder. Grey
RAL7024.
Technical data
MODELS
Power supply (V - 50/60 Hz)
BUS connection (CXN Unit)
Power (W)
Absorbed current (mA)
Operating temperature (°C)
Storage temperature (°C)*
Protection rating (IP)
Average life (cycles)**
(*) Before installing the product, keep it at room temperature where it has previously been stored
or transported at a very high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage,
installation and maintenance conditions. It is also infl uenced by other factors, such as climatic and
environmental conditions.
A
Description of parts
1
Front cover
2
Selector
5
Recessed gasket
4
Recessed casing
5
Customised keys
B
Control board
6
Status warning LED
7
Set-up DIP switch
8
Terminal block
SELD2BDG
BUS CXN
1
0.35
25
-20 ÷ +55
-25 ÷ +70
44
500000