Télécharger Imprimer la page

Glacier bay FS2A0004CP Guide D'installation Et D'entretien page 6

Robinet de lavabo à deux poignées

Publicité

Operation
1
Flushing and checking for leaks
IMPORTANT: After installation is complete, remove
the aerator to flush the water lines. Do not lose the
gasket in the aerator.
Ensure the handle is in the off position. Turn on the
water supply and check for leaks. If you discover any
leaks, check your connections to ensure they are
installed properly.
Remove the aerator (B) and housing (if applicable). Turn
on the hot and cold handles to allow the water to run for
at least one minute. This flushes away any debris that
could cause damage to internal parts.
Turn off the water and reinstall the aerator and housing
(if applicable).
Care and Cleaning
To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
NOTE: Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed
below.
Problem
There are leaks from the
handle.
The aerator leaks or has a
reduced water flow.
The sink drain at the base of
the sink is leaking.
The water will not shut off
completely.
Possible Cause
The bonnet nut is loose.
The O-ring on the cartridge is
dirty or damaged.
The aerator is dirty or mis-fitted.
The cartridge may be clogged.
The sink surface is rough or
irregular.
The cartridge bonnet nut
is loose or cartridge is not
positioned correctly.
The cartridge is damaged.
B
Tighten the bonnet nut.
Clean or replace the O-ring.
Remove the aerator and check for
debris.
Remove the cartridge and check for
debris.
Ensure the aerator is properly
installed.
Retighten and test for leaks.
Reinstall the cartridge after cleaning
and tighten the bonnet nut.
If the problem still exists, replace the
cartridge.
6
A
Solution

Publicité

loading

Ce manuel est également adapté pour:

Fs2a0004blFs2a0004cz1001-036-4241001-184-8341001-536-032