Télécharger Imprimer la page

Milwaukee TEMP-GUNS 2267-20 Manuel De L'utilisateur page 4

A infrarouge
Masquer les pouces Voir aussi pour TEMP-GUNS 2267-20:

Publicité

FUNCTIONAL DESCRIPTION
4
7
8
CAN ICES-3 B -NMB-3 B
IEC 60825-1:2014-05 P ≤ 1mW @ 630nm - 670nm
COMPLIES WITH 21 CFR 1040.10 AND 1040.11 EXCEPT FOR
3
CONFORMANCE WITH IEC 60825-1 ED. 3., AS DESCRIBED IN LASER
CAT.NO. 226 -20
8
9 V
PP3/6LR61 CAN ICES-3 B -NMB-3 B
(
)
IEC 60825-1:2014-05 P ≤ 1mW @ 630nm - 670nm
AVG
COMPLIES WITH 21 CFR 1040.10 AND 1040.11 EXCEPT FOR
CONFORMANCE WITH IEC 60825-1 ED. 3., AS DESCRIBED
IN LASER NOTICE NO. 56, DATED MAY 8, 2019.
1. Laser window
2. 2267-20 nameplate
3. 2268-20 nameplate
4. Trigger
5. Display
6. Mode/Set/Alarm buttons
7. Battery door lock
8. Battery door
9. Battery indicator
10. Hold indicator
11. Laser active indicator
12. Trigger lock indicator
13. Alarm indicator
14. °C or °F indicator
15. Primary measurement
16. Secondary measurement
17. Mode indicator
10 11
1
9
17
16
2
CAT.NO. 2267-20
9 V
SER.
(
PP3/6LR61
)
10:1
INFRARED
TEMP-GUN
Milwaukee Tool, Brook eld, WI 53005 USA
( )
( )
AVG
NOTICE NO. 56, DATED MAY 8, 2019.
SER.
( )
( )
12:1
INFRARED
TEMP-GUN
Milwaukee Tool, Brook eld, WI 53005 USA
5
Loading/Changing the Battery
12
1. Using a flat screwdriver,
13
rotate the battery door lock
to the unlocked position
and open the battery door.
2. Connect one (1) 9V battery
14
to the connector block. Fit
the battery into the com-
partment.
15
3. Close the battery door.
Turn the battery door lock
to the locked position.
Selecting Celsius or Fahrenheit
To set the temperature scale, pull the trigger and
then press the SET button three times. Press the
buttons above the up and down arrows to toggle
between °C and °F. Wait 5 seconds for the setting
to save and exit.
To turn the laser on and off, pull the trigger and then
press the SET button four times. Press the buttons
above the up and down arrows to toggle between
ON and OFF. Wait 5 seconds for the setting to save
and exit.
Scanning Object Temperature
1. Pull and hold the trigger for at least 2 seconds
and scan the surface temperature of an object. A
laser pointer is used for aiming on the area being
scanned.
NOTE: The object should be larger
than the spot being scanned. If not,
readings will be affected. See Dis-
tance To Spot for necessary object
size.
2. As you continue to hold the trigger,
6
the icon
the primary measurement (surface
temperature) and secondary mea-
surement (maximum, minimum,
average, or differential tempera-
ture) readings.
3. Release the trigger. HOLD is
displayed until the screen shuts off in about ten
seconds.
To turn the trigger lock on and off, pull the trigger
and then press the SET button five times. Press the
buttons above the up and down arrows to toggle
between ON and OFF. Wait 5 seconds for the setting
to save and exit.
Press the ALARM button to turn on
the alarm function. The bell icon is
displayed. If the temperature reading
is outside the preset range, the tem-
perature reading will flash.
4
ASSEMBLY
Setting the Laser
OPERATION
is displayed along with
Setting the Trigger Lock
Temperature Alarm

Publicité

loading

Ce manuel est également adapté pour:

Temp-guns 2268-20