UPS IMPORTANT NOTES
•To set up this backup power mode, just keep the battery charging while
running your machine.
•When there is no power outage, the battery will run the wall power through
a Bypass (pass-through) increasing the battery's lifespan and ensuring
proper performance.
•When a power outage occurs, the battery senses the bypass has zero
current flow and switches instantaneously to battery power. You would
sleep through the power outage uninterrupted.
•Note: The Zopec Explore™ Mini cannot be used in UPS configuration with
the ResMed AirMini 20W power cord due to it's low Wattage. The ResMed
AirMini 20W power cord can only be used to recharge the battery with the
corresponding charging adapter.
•Note: To use the Zopec Explore™ Mini in the UPS configuration with the
Zopec Explore™ USB-C Fast Charging Adapter, the Heated Tube MUST be
OFF. Otherwise, your PAP device will start drawing power from the battery.
If you see the battery starting to drain, then please turn the Heated Humidifi-
er and Heated Tube OFF.
•This battery comes with all safety features including over current, over
voltage, and over temp protection.
7.2. UNINTERRUPTIBLE POWER
SUPPLY (UPS) FOR POWER
OUTAGES
To use the Zopec Explore™ Mini as a
UPS please connect the battery to your
compatible PAP device setup. Next
connect it to charge using one of the
following options:
•The Zopec Explore™ USB-C Fast
Charging Adapter
(Model #:
EMAUSBC)
or an equivalent 65W
USB-C charger.
Note: the Heated Tube
CANNOT be used in this
configuration.
(See diagram D)
•Your PAP device's power cord and it's
compatible charging adapter cable.
.1.The ResMed AirSense 10 power cord
will connect directly to the Explore Mini
DC Output port.
.2.The AirMini and AirSense 11 will
require the AirMini / AirSense 11
Charging Adapter to be connected to
the original ResMed AirMini or AirSense
11 power cord and to the DC Output
port of the Zopec Explore™ Mini. (See
diagram C below)
- 5 -
8. UNLIMITED LINKING TECHNOLOGY
•To get additional PAP device runtime, you can purchase multiple Zopec
Explore™ Mini batteries and link them together increasing capacity. There is
no limit on how many batteries you can link together.
•To link 2 batteries, use the included AirSense 10 Series & VAuto Cable.
Plug the yellow tip of the cable into the DC Output port of the 1st battery and
the other end of the cable into the DC Input port of the 2nd battery. Make
sure both batteries are powered On. Repeat these steps to link more
batteries. Please note that
the PAP Device must plug into the first battery in
the
series.
•For backup power mode as USP, just have the last battery in the link
charging (see section 6 for details) Note: cannot be used to charge multiple
connected batteries with the use of the Zopec Explore™ USB-C Fast
Charging Adapter.
Note: When drawing from multiple batteries, it doesn't have a consistent
order on which battery it will draw first. That is normal. Every battery's
internal resistance is different and your CPAP machine will draw power
based on the path of least resistance.
9. BATTERY RUN TIME TABLE
Machine
Machine Model
Brand
S9, AirSense AutoSet
10 or 11
ResMed
AirCurve 10 VAUTO
BiPap
AirMini
DreamStation Auto
1 or 2
Philips
Respironics
DreamStation BiPap
DreamStation Go
Transcend
Micro
Löwenstein
PrismaSMART
Medical
3B Medical
Luna/G3 Series
Resvent
iBreeze Series
Breas HDM
Z1 / Z2
Drive
IntelliPap I / II
DeVilbiss
Pressure
Heated
Heated
Runtime
(cm H2O)
Humidifier
Tube
(Hours)
10
OFF
OFF
12.5
15
OFF
OFF
10.5
10
On (4)
OFF
6
15
On (4)
OFF
4.5
IPAP=20,
OFF
OFF
9.5
EPAP=15
IPAP=20,
On (4)
OFF
4
EPAP=15
10
OFF
OFF
15
15
OFF
OFF
13.5
10
OFF
OFF
16
15
OFF
OFF
12
10
On (3)
OFF
6
15
On (3)
OFF
4.5
IPAP=20,
OFF
OFF
9.5
EPAP=15
IPAP=20,
On (3)
OFF
4
EPAP=15
10
OFF
OFF
16
15
OFF
OFF
12.5
10
OFF
OFF
16
10
OFF
OFF
13
10
OFF
OFF
13
10
OFF
OFF
13
10
OFF
OFF
16
10
OFF
OFF
13
- 6 -

Publicité

loading