V1.0
ASSEMBLY & INSTALLATION
Dashed numbers in parenthesis (Fig. 1-1) refer to a specific
point in an illustration or image.
1.
The control box has two sets of
parallel cables (Fig. 1-4). Connect one
set to the control panel parallel ports
on the first generator (Fig. 1-1). Make
sure the cables match the correct
polarity.
2.
Connect the second set of parallel
cables to the same parallel ports on
the other inverter generator.
3.
Attach a ground wire (Fig. 1-3) to the ground bolt (Fig. 1-2) on the first
generator. Attach a separate ground wire to the other generator in the
same way. Consult the generator manual for grounding instructions.
OPERATION
NOTICE! Avoid overloading the generators (30A). An overload that only
slightly exceeds the 30A rating may fail to trip the overload circuit.
This can shorten the life of the generator and parallel cable box.
IMPORTANT! Only use one parallel box outlet at a time. Using both can
cause an overload.
Consult the generator manual for instructions on preparing and starting the
generators when connected to the parallel cable box.
1.
Make sure the green power lights (Fig.
2-1) on both generators are green
before connecting any devices. Restart
both generators if one, or both, power
lights are not lit.
2.
High electrical loads may overload
the generators. Make sure the Eco
button (Fig. 2-2) is OFF to allow
maximum power.
3.
The AC output will switch off if
power output exceeds 30A.
4.
Plug a power plug into the NEMA L5-
30R or the NEMA TT-30R power outlet (Fig. 3), but not both.