"Live Display" program – VeGA
Requirements for operation:
Device
Version of software in the device
VeGA
All
Program start-up
1
2
Fig. 60
Device search
1
Truma Diagnose Tool / Livwe Display
2
File
Tools
?
Start
Stop
Properties
Select language
3
Fig. 61
The operating parameters will be displayed in a box if the
search is successful.
1
Fig. 62
Screen displaying current action
1 Device search
2 Hardware and software initialisation
3 Communication between PC and device
– Green flashing light – error-free communication
– Red light – interruption
28
1 Start the program by
double-clicking on the
"Truma Diagnose Tool"
icon on the desktop.
2 Select "Live Display" to
start the program.
1 Click on "Tools".
2 Click on "Start".
2
3
Display of errors and actions
Select "Errors" tab to go to the relevant display.
1 Click on "Errors".
2 Description of error and list of actions required to remedy
error
1
2
Fig. 63
Service functions
1 Click on the "Service functions" tab to enable these
functions.
2 Display of results
3 Click on "Fan test" to start testing the fans.
4 Click on "Air sensor test" to start testing the air sensors.
5 Click on "Bleed the sulphur removal unit" to evacuate the
air from the sulphur removal unit.
A small amount of gas may escape during the
bleeding process therefore ensure that there is good
ventilation.
Follow the on-screen instructions (6).
1
2
3
Fig. 64
4
5
6

Publicité