"Error Explorer" program – Combi, Mover®
Requirements for operation:
Device
Version of software in the device
Combi (Gas)
> V 03.00.00
Combi D
> V 04.00.00
Mover®
All
Mover® S from 01/2008
Program start-up
1
2
Fig. 25
Device search
1
Truma Diagnose Tool / Error Explorer
2
File
Tools
?
Start
Stop
Properties
More...
Select language
3
Fig. 26
Error memory readout
6
5
1
2
Fig. 27
Screen displaying current action
1 Device search
2 Error memory readout
3 Error memory content will be prepared for display
4 Status bar
5 Device which is connected to the "Diagnose Tool"
6 Information on the device
Field
Meaning
Master
M(aster) / S(lave)
FID
Device code
VID
Device type
NAD
Network address
SWVer
Version of software in the device
TINVer
Version of TIN bus
22
1 Start the program by
double-clicking on the
"Truma Diagnose Tool"
icon on the desktop.
2 Start "Error Explorer" in
the selection window.
1 Click on "Tools".
2 Click on "Start".
3 Search results or
information on the
device detected (see
"Error memory readout")
4
3
Error list / action list display
Select the "Errors" tab to go to the relevant display.
7
1
5
6
Fig. 28
1 Error list
– The current error is marked with an asterisk (*).
If there is no asterisk (*), the current error is undefined.
– Click on an error to view list of actions.
2 Error description – detailed information about the error
(see "Details window")
3 Flash code
4 One or more actions required to remedy the error
5 Grouping of errors with "]" – meaning depends on test
object
Combi – simultaneous occurrence of errors within a data
packet
Mover® – same error occurred several times in sequence
6 Mover® – A fatal error is also marked with (X).
7 Product name of detected device, e.g. Combi
The data in the error / action list are valid for Mover®
from 09/2012.
Details window
Error details are intended for specially trained service
personnel only.
The Combi Gas device is shown in the example.
2
Truma Diagnose Tool / Error Explorer
Combi
?
File
Tools
Start
Product(s)
Fehler
Fehler
F
3
Stop
1
Properties
Error #
Eehler Informatio
E eh
ehler Informatio
hler Informatio
More ...
Select language
127 (*)
4
113
127
Fig. 29
Error list storage
The error list can be saved and emailed for reference when
communicating with Truma.
1
Truma Diagnose Tool / Error Explorer
File
Tools
Combi
?
2
Open ...
Open ...
Save as ...
Save as ...
Print
Print
Live Display
Live Display
Exit
Exit
Fig. 30
<File name>.tef – .tef = extension of the file name for the bi-
nary error log
2
3
4
1 Click on the relevant
error.
2 Click on "Tools".
3 Click on "More ..." for
details on the error.
4 Detailed information on
the error
1 Click on "File".
2 Click on "Save as ...".
– Accept or change <file
name>.
– Click on "Save".