Step 3 — LUMINAIRE AIMING
Two sighting systems are provided for your convenience.
Use the sight system which is most easily accessed.
Optical Sight:
A . Rotate sight into vertical
position.
B . Align the reference
mark of top of reflector
flange with notch in
sight for proper aiming.
Base Sight
A. Rotate front and back
sight into vertical
position.
B. Align the two sighting
holes for proper aiming.
STEP 5
Connect power cable to suitable supply in accordance
with all applicable codes.
INSTALLATION CLEANING
DO NOT CLEAN INTERNAL OPTICAL SYSTEM
The UltraMSport floodlight has been specially
cleaned at the factory. Field cleaning of the internal
optical system during installation is not recommended.
EXTERNAL CLEANING
Initial cleaning of the outside of the glass lens may be
required to ensure optimum optical efficiency.
Clean front glass with a mild soap and water solution,
rinse clean and wipe dry.
CAUTION
Risk of burn
• Allow lamp/fixture to cool before
handling
LAMP
REPLACEMENT
A . Insert the lamp terminal into the socket terminal
(a) at both ends of the lamp and tighten screws.
Step 4
After positioning luminaire, tighten all mounting
hardware.
CLEANING INSTRUCTIONS AND CAUTIONS
Caution: do not touch quartz tube with bare hands! If
lamp is handled, finger prints, grease or oils should be
removed from the lamp with isopropyl alcohol. This will
remove materials which cause whitish spotting and
premature lamp failure. Dry lamp carefully with cotton or
clean cloth.
PERIODIC CLEANING WHEN RELAMPING
INTERNAL
Should the internal reflector system require
cleaning, use only non-abrasive, neutral (pH 6-8) cleaner
containing no chlorinated or aromatic hydrocarbons.
Rinse clean and wipe dry.
EXTERNAL
Clean front glass with a mild soap and water solution,
rinse clean and wipe dry.
B . Snap the lamp ends into the lamp retaining
clips (b).
C . Close and rebolt the relamping door. Tighten
bolts to 50 in. lbs. torque.