Compact single-phase type 2 (or 3) surge protector - 230
V - Monobloc
Electrical Characteristics
SPD type
following IEC test
Network
AC system
Nominal line voltage
Max. AC operating voltage L-N
Max. load current
Temporary Over Voltage (TOV) Charasteristics - 5
sec.
without disconnection
Temporary Over Voltage (TOV) Charasteristics - 120
mn
without disconnection or with safety disconnection
Operating current
Continious current at Uc
Follow current
Nominal discharge current
15 x 8/20 µs impulses
Max. discharge current
max. withstand @ 8/20 µs by pole
Total discharge current
max. total withstand @ 8/20µs
Withstand on Combinaison waveform IEC 61643-11
Class III test: 1.2/50µs - 8/20µs
Withstand on overvoltages IEEE C62.41.1
Admissible short-circuit current
Connection mode(s)
Protection mode(s)
Protection level CM/DM
@ In (8/20µs)
Internal short circuit protection
Internal Thermal protection
Mechanical Characteristics
SPD configuration
Connection to Network
Format
Mounting
Housing material
Operating temperature
Protection rating
Failsafe behavior
Disconnection indicator
Remote signaling of disconnection
Dimensions
2 (ou 3)
230 V single-phase
TN
Un
230 Vac
Uc
275 Vac
IL
16 A
UT
335 Vac withstand
UT
440 Vac disconnection
Ic
None
If
None
In
5 kA
Imax
10 kA
Imax
20 kA
total
Uoc
10 kV
10 kV
Isccr
10000 A
L/N/PE
Common/Differential mode
Up mc/
1.5 kV / 1 kV
md
No
Yes
Single phase
by screw terminals : 2.5 mm² max.
Plug-in modular box
Symmetrical rail 35 mm (EN60715)
Thermoplastic UL94-V0
-40/+85°C
IP20
AC network cutt-off
Red light on
no
See diagram
CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel: +33 1 41 23 50 23 • e-mail: contact@citel.fr • www.citel.fr
201910 • CITEL2CP-DS98L-400-en • Document Subject To Modifications Without Notice
DS98L-400
Cost effective single-phase surge protector
Safety disconnection in-line
Double connection in series
Common/Differential mode
V: Varistor
GSG: Specific gas tube
LED: Disconnection indicator
Ft: Thermal fuse
t°: Thermal system disconnection
LED

Publicité

loading

Sommaire des Matières pour Citel DS98L-400

  • Page 1 Remote signaling of disconnection Dimensions See diagram CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel: +33 1 41 23 50 23 • e-mail: contact@citel.fr • www.citel.fr 201910 • CITEL2CP-DS98L-400-en • Document Subject To Modifications Without Notice...
  • Page 2 IEC 61643-11 / EN 61643-11 / UL1449 4ed. Certification Part Number 3519011 CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel: +33 1 41 23 50 23 • e-mail: contact@citel.fr • www.citel.fr 201910 • CITEL2CP-DS98L-400-en • Document Subject To Modifications Without Notice...
  • Page 3 Technical Data Application example Installation N131002d INSTALLATION INSTRUCTIONS - NOTICE D'INSTALLATION 0.5-2.5mm² 2000 m max. NOTICIA DE INSTALACIÓN - INSTALLATIONSHINWEISE #20-13 AWG Switchboard 6500 ft max. ISTRUZIONI PER L'INSTALLAZIONE INSTRUCOES DE INSTALACAO - MONTÁŽNÍ NÁVOD -40/+85°C max. -40/+185°F max. 10 mm - 安装指导书...
  • Page 4 - 请根据不同的电源网络制式选用浪涌保护器,参见 montážních pokynů. www.citel2cp.com Table 1; - Svodiče přepětí je zapotřebí zvolit a používat tak, aby www.citel.de odpovídaly napájecí síti (viz tabulka 1). www.citel.us - 请在浪涌保护器前端安装规定的熔断器,参见 - Potřeba instalace pojistek pro předjištění před svodiče www.citel.com.cn Table 2;...

Ce manuel est également adapté pour:

Ds98l serie