3 Installation instructions
3.1 Mounting the heater
Wall mounting
: Material damages!
NOTICE
Use screws that are suitable for the wall
material and the weight of the heater.
1. Use a marker to mark the
drilling position on the wall
and confirm the marked
position.
Tips: When marking the position, ensure that the
n
water heater is not less than 300 mm away from
the wall to leave space for opening the electrical
cover for maintenance in the future. The installation
position should be as close to the water intake
point as possible.
2. Use a 10mm impact drill to drill two holes in the
wall. The depth of the holes should not be less than
the length of the expansion screw straight rod.
Drywall
Plywood
Bracket
Fig. 5
Bracket
Fig. 6
CAUTION
The appliance must be hung securely to
prevent personal injury and property damage
from falling.
Floor mounting
Heater can sit on floor.
n
0.39" (10 mm)
2.56" (65 mm)
Install the wall hole
Studs
Anchors
3.2 Pipe connections
Connect the cold water inlet pipe to the inlet
n
tapping (marked with a blue ring).
Ensure a isolation valve is installed on the cold
n
water supply to the water heater.
Connect the hot water outlet pipe to the outlet
n
tapping (marked with a red ring).
CAUTION
To reduce the risk of excessive pressures
and temperatures in this water heater:
Install the supplied temperature and
n
pressure protective equipment required
by local codes but not less than a
combination temperature and pressure
relief valve certified by a nationally
recognized testing laboratory that
maintains periodic inspection of
production of listed equipment or
materials, as meeting the requirements
for Relief Valves and Automatic Gas
Shut-off Devices for Hot Water Supply
Systems, ANSIZ21.22.
The supplied temperature and pressure relief valve is
marked with a maximum set pressure (150 psi) that
does not exceed the marked maximum working
pressure of the water heater.
Install the Temperature and pressure relief valve in
n
the opening provided and marked for this purpose
in the water heater.
Orient it or provide tubing so that any discharge
n
from the valve will exit within 6 inches above, or at
any distance below, the structural floor, and
cannot contact any live electrical part. The
discharge opening must not be blocked or reduced
in size under any circumstances.
Hot water Outlet
Temperature
Pressure
Relief Valve
Fig. 7
Installation instructions
Cold water Inlet
Discharge Pipe
(DO NOT CAP OR
PLUG)
6" (15.24 cm) Max
Floor Drain
09