Accuracy Issues
Small accuracy errors of 1/16" or less:
• Be sure the jaws fit tight and flat when in use and
when calibrating
• Be sure the lock knob is tight
• Check for loose or flexing brackets
• Make sure that the scale is perpendicular to the
table in all planes
Large accuracy errors of .200" or more:
• An error of exactly .200" is a very common error
number with these devices or even a multiple of it
Like .400, .600, 1.200 etc. Usually this only
happens when the readout is either moved very quickly
(more than 3 feet per second). Follow the same
steps outlined in "Loses calibration" section above.