Télécharger Imprimer la page

U-Line UCFZ527-SG31A Manuel D'utilisation page 20

Publicité

Power supply: 12 VAC (+10% -15%) 50/60Hz (±3Hz) max 4VA insulated - 12VDC max 3,5W
Over voltage category: III.
Analogue input: 2 for NTC/PTC nodes (Cabinet probe and Evaporator probe)
Sensor range:
-PTC: from -50°C to 150°C (from -58 to 302°F)
-NTC: from -40°C to 105°C (from -40 to 221°F)
Sensitivity: 0,1°C (1°F)
Digital inputs: 1 (microport) for NO/NC contac (dry contact: 5VDC, 2mA)
Digital outputs: 6 electro-mechanical relays
Relay K1: SPST, 16A res. @250VCA
Relay K2: SPDT, 8A res @250VCA
Relay K3: SPST, 16A res @250VCA
Relay K4: SPST, 8A res @250VCA
Relay K5: SPST, 5A res @250VCA
Relay K6: SPDT, 8A res @250VCA
Alarm buzzer: Incorporated.
The maximum current applicable to the loads is 24A.
Communication port: 1 TTL MODBUS slave port for EVconnect APP or BMS (by request)
3.2 REGULATION
Once set a desired temperature required for the products storage within the operational range of
each models, the regulation of the cooling system is controlled by the temperature measured by
the control probe with a positive differential from the set point: when the temperature rises up to the
set point plus differential the compressor starts to pull down the temperature and it turns off when
the desired set point is reached again.
In case of faulty probe the compressor activation is timed through the parameter "C4" and "C5"