Vox control with relay output in timed mode or latching mode.
In timed mode the relay is activated for the set time, after this time the relay is deactivated.
In latching mode the relay is permanently activated until it is deactivated with the reset.
It incorporates potentiometers for adjusting sensitivity and timing, timed / latching mode switch, reset input, indicator
led, and protection against polarity reversal.
Especially suitable for automation applications in processes where it is required to detect an audio signal.
POWER SUPPLY : Connect the 12 Vdc power supply to the POWER terminal respecting the ± polarity.
Connect a pushbutton to the Reset input. Install a switch for protection and safety, according to CE standard.
Before activating the switch, make the rest of the circuit connections. To supply 230 VAC use our recommended FE
103 or FE 300 power supplies.
OPERATION :Connect the input signal to the terminals. The cable length should be as short as possible. You must
use shielded low frequency cable. The input signal can be provided by auxiliary sockets, mixers, etc., it cannot
exceed 300mV maximum level.
Select timed or latching mode with the circuit switch. Adjust the sensitivity potentiometer. If you have selected the
timed mode, also adjust the time potentiometer.
Will connect the output through the relay, remaining activated according to the selected mode.
In timed mode, each time the circuit receives an audio signal, the output will be activated for the adjusted time, after
which the output will be deactivated. The output can be manually deactivated before the end of the time through the
Reset input.
In interlock mode, the circuit, every time it receives an audio signal, the output will be activated until it is manually
deactivated through the Reset input.
VOX CONTROL Timer / Bistable
CONTROLE VOX Temporisateur / Bistable
VOX CONTROL Temporizador/Biestable
VOX CONTROL Temporitzador / Biestable
www.cebek.com
PM-16
Technical characteristics
Voltage : 12 Vdc
Minimum Input Signal :10 mV.
Maximum Input Signal : 300 mV
Consumption : 2 to 60 mA
Frequencies margin : 30 – 12,000 Hz
Functions relay : Timer or Bistable
Function Timer : 1 seg to 4 min
Function Bistable : with reset
Output type : Relay - NO / NC
Max. Output load : 7A ( 2A for inductive loads)
Operating Indicator Led : Yes.
Protection Inversion Polarity : Yes.
Sizes : 72 x 42 x 20 mm.
Weight : 30,3 gr.
Cable measure : 10cm.
Din rail : C-7562
-
sat@fadisel.com

Publicité

loading

Sommaire des Matières pour CEBEK PM-16

  • Page 1 VOX CONTROL Timer / Bistable CONTROLE VOX Temporisateur / Bistable VOX CONTROL Temporizador/Biestable VOX CONTROL Temporitzador / Biestable PM-16 Technical characteristics Voltage : 12 Vdc Minimum Input Signal :10 mV. Maximum Input Signal : 300 mV Consumption : 2 to 60 mA Frequencies margin : 30 –...
  • Page 2 PM-16 Contrôle Vox avec sortie relais en mode temporisé ou en mode verrouillage. En mode temporisé, le relais est activé pour le temps défini, passé ce temps, le relais est désactivé. En mode de verrouillage, le relais est activé en permanence jusqu'à ce qu'il soit désactivé avec la Reset.
  • Page 3 PM-16 Vox control amb sortida a relé en mode temporitzat o manera enclavament. En mode temporitzat el relé s'activa el temps ajustat, passat aquest temps el relé es desactiva. En mode enclavament el relé s'activa de manera permanent fins que es desactivi amb el reset.
  • Page 4 PM-16 CONNEXIÓ DE SORTIDA: La sortida es realitza mitjançant un relè, dispositiu que admet qualsevol tipus de càrrega que no superi els 7A. El relé disposa de tres terminals de sortida. El Normalment obert en repòs (NA), el Normalment tancat en repòs (NC), i el Comú (CO). El funcionament d'aquest mecanisme és idèntic a un interruptor on els seus dos terminals seran el NA i el Comú.
  • Page 5 PM-16 Note. This printed circuit is used for several models, it is normal that there are free spaces. Note. Ce circuit imprimé est utilisé pour plusieurs modèles, il est normal qu'il y ait des espaces libres . Nota. Este circuito impreso se emplea para varios modelos , es normal que hayan espacios libres.