ACTpro 1520e/1500e Door Controller – Installation and Operating Instructions
2.4 Typical wiring of ACTpro 1520e/1500e
Label Description
A
Door contact, normally closed
B
Push to exit, normally open
C
Door networks
D
Controller network
Break glass monitoring, normally
E
closed
2.4.1 Wiring exit readers
For clock and data readers, wire exit readers in parallel but leave the sense line unconnected.
For Wiegand readers, wire the DATA 0 of the exit reader to SENSE on the ACTpro 1520e.
Max length: 100m with 12V DC
Cable: 8 core screened Belden 9504 or equivalent
© Vanderbilt 2018
Label Description
F
ACT reader wire colour coding
Ethernet: RJ45
G
Note: All IP device must have a valid IP Address.
Important: Place varistor across all lock terminals.
H
Note: Diagram shows normally energised Magnetic
Lock.
J
Break glass unit (double pole)
EN – 9
Installation
A-100440
01.02.2018