Specifications
DC Voltage (Auto ranging)
Range
Resolution
600mV
6V
60V
600V
1000V
Internal impedance: 10MΩ
Overload protection : 600V DC/AC rms
Max. Input Voltage: 600V DC
AC Voltage (Auto ranging)
Range
Resolution
600mV
6V
60V
600V
Internal impedance: 10MΩ
Frequency Range: 40Hz ~ 400Hz
Overload protection : 600V DC/AC rms
Response: Average value calibrated in effective sine wave values
Max. Input Voltage: 600V AC rms
Resistance (Auto ranging)
Range
Resolution
600Ω
6KΩ
60KΩ
600KΩ
6MΩ
60MΩ
Open Circuit Voltage: about 0.25V
Overload protection: 250V DC/AC rms
Frequence (Auto Ranging) (only2015B)
Range
0 ~ 60MHz(voltage)
0 ~ 1KHz(clamp)
Duty Cycle
Range
Resolution
0.01%~99.9%
For value between 10% and 90% duty cycle at 50Hz
4
Precision
0.1mV
±(0.8% of rdg + 5dgts)
1mV
10mV
±(0.8% of rdg + 3dgts)
100mV
1V
±(1.0% of rdg + 5dgts)
Precision
0.1mV
±(1.2% of rdg + 8dgts)
1mV
±(1.0% of rdg + 8dgts)
10mV
100mV
±(1.2% of rdg + 8dgts)
Precision
0.1Ω
10Ω
±(1.5% of rdg + 5dgts)
100Ω
1KΩ
10KΩ
Precision
±(1.0% of rdg + 5dgts)
±(1.5% of rdg + 5dgts)
Precision
0.01%
±1%
WWW.NIKOLAOUTOOLS.COM
AC Current (Auto ranging)
Range
Resolution
2-20A
200-600A
Measuring voltage drop: 200mV
Frequency Range: 40 to 200Hz
Temperature (only 2015B)
Range
Resolution
-40 ~ 1370°C
1°C
-40 ~ 2000°F
1°F
Internal impedance: 10MΩ
Frequency Range: 40Hz ~ 400Hz
Overload protection : 600V DC/AC rms
Response : Average value calibrated in effective sine wave values
Max. Input Voltage: 600V AC rms
Overload protection: 250V DC/AC rms
Diode and Continuity
Range
Introduction
The approximate for-
ward voltage drop will
be displayed
The built-in buzzer will
sound if the resistance is
less than about 30Ω.
1.Overload protection: 250V DC/AC rms
2. For continuity test: When the resistance is between 30Ω and 100Ω, the
buzzer may sound or may not sound. When the resistance is more than
100Ω, the buzzer will not sound.
Capacitance (Auto Ranging)
Range
60nF/600nF/6uF
60uF/60mF(15Sec)
Technical Data
DCV
ACV
ACA
OHM
400-4K-40K-400K-4M-40MΩ ±1.0%
Precision
100mA
±(3.0% of rdg + 5dgts)
1A
Precision
-40°C~150°C:±(1.2% + 4)
150°C~1370°C:±(2.5% + 4)
-40°F~302°F:±(5% + 4)
3°F~2000°F:±(2.5% + 4)
Remark
Open circuit voltage: about
1.5V
Open circuit voltage: about
0.5V
Precision
±(5.0% of rdg + 8dgts)
0-600V ±1.0%
0-600V ±1.2%
2-20-200-600A ±2.0%

Publicité

loading

Ce manuel est également adapté pour:

028444