When opening covers or removing parts, unless this is possible by hand, current-carrying parts can
be exposed. Connection points can also be current-carrying. Before maintenance, repair or
replacement of parts or assemblies, the appliance must be disconnected from all electrical circuits
if opening the appliance is necessary. If maintenance or repair of the opened appliance while
connected to power is unavoidable after this, this may only be carried out by an expert familiar
with the associated risks and relevant regulations. Components in the appliance can still be
charged even if the appliance has been separated from all electrical circuits.
MAINTENANCE
Apart from occasional dry cleaning of the housing, the BHC4001 is maintenance-free. It should
never be opened/disassembled. If the appiance is nevertheless opened, the guarantee is voided.
Use a clean, dry, lint-free, antistatic cleaning cloth to clean.
Please note!
Do not use any cleaning agents containing carbon or benzene, alcohol or similar substances for
cleaning. This will harm the surface of the housing. In addition, the vapours are injurious to health
and explosive. Do not use any sharp-edged instruments, screwdrivers, metal brushes or similar
tools for cleaning.

TECHNICAL DATA

BHC4001
Mains voltage
Max. load at 20 °C ambient temperature
Power consumption
Connection diameter
Installation with two lamps
Operating temperature
IP protection class
Dimensions
WARNING
The BHC4001 may not be directly installed on combustible material, e.g. wood.
The heat sink must attached at a distance to the mounting wall with the help of spacers to facilitate
heat dissipation.
Installation and maintenance of the appliances must be carried out by qualified and trained staff
in accordance with the current issue of the IEE wiring regulations (BS7671). These regulations
include important requirements for the safety of electrical installations (international standards
see IEC guideline IEC950).
Packaging
Packaging materials are chosen with consideration to environment and are therefore recyclable.
Handling of product at end of working life
The symbol left implies this product may contain substances necessary for functionality of
product but potentially dangerous for the environment. The product should not be
disposed mixed with general household waste but delivered to a designated collection
point for environmental recycling. Please contact local authority for further details of your
nearest designated collection point.
230V AC +/- 10% 50Hz
4kW
50mA
Max. cable entry 2,5mm²
Must be parallel connected
-20°C to 30°C
IP65
B = 280mm D = 200mm H = 80mm