INSTALLATION GUIDE
General Installation Information ................................................................................................ 2
Nomenclature ................................................................................................................................... 6
Water Quality ................................................................................................................................... 13
Hot Water Generator Connections .......................................................................................... 14
Electrical Connections .................................................................................................................. 15
Electronic Thermostat Installation ........................................................................................... 16
Blower Performance Data ........................................................................................................... 17
Dimensional Data ............................................................................................................................ 18
Physical Data .................................................................................................................................... 20
Reference Calculations ................................................................................................................. 21
Operating Limits.............................................................................................................................. 21
Revision Guide ................................................................................................................................. 23
WARNING: Before performing service or maintenance
operations on the system, turn off main power switches
to the unit. Electrical shock could cause serious personal
injury.
WARNING: All products are designed, tested, and
manufactured to comply with the latest publicly released
and available edition of UL 60335-2-40 for electrical
safety certification. All field electrical connections must
follow the National Electrical Code (NEC) guide standards
and / or any local codes that may be applicable for the
installation.
WARNING: Only factory authorized personnel are
approved for startup, check test and commissioning of
this unit.
INSTALLER: Please take the time to read and understand
these instructions prior to any installation. Installer must
give a copy of this manual to the owner.
Definition of Warnings and Symbols
DANGER
WARNING
CAUTION
NOTICE
R-454B / 60Hz
WARNING
Indicates a situation that results in death or
serious injury.
Indicates a situation that could result in
death or serious injury.
Indicates a situation that could result in
minor or moderate injury.
Indicates a situation that could result in
equipment or property damage.
For the User
This appliance is not intended for use by persons (including
children) with reduced physical, sensory, or mental capabilities,
or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
Keep this manual in a safe place in order to provide your
service personnel with necessary information.
NOTICE
NOTICE: To avoid equipment damage, do not leave the system
filled in a building without heat during cold weather, unless
adequate freeze protection levels of antifreeze are used. Heat
exchangers do not fully drain and will freeze unless protected,
causing permanent damage.
IGW3-0019S
WARNING

Publicité

loading

Sommaire des Matières pour GeoSmart ENERGY IGW3-0019S

  • Page 1 INSTALLATION GUIDE R-454B / 60Hz IGW3-0019S General Installation Information ....................2 Nomenclature ........................... 6 Water Quality ........................... 13 Hot Water Generator Connections ..................14 Electrical Connections ........................15 Electronic Thermostat Installation ................... 16 Blower Performance Data ......................17 Dimensional Data ..........................18 Physical Data ............................
  • Page 2 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information NOTICE: Do not store or install units in corrosive environments No person carrying out work in relation to a REFRIGERATING SYSTEM which involves exposing any pipe work shall use any or in locations subject to temperature or humidity extremes.
  • Page 3 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information Installation Space Requirements WARNING Ventilated Area: ensure that the area is in the open or that it NOTE: Equipment with refrigerant charge less than 64 oz does is adequately ventilated before breaking into the system of not require have a minimum floor area requirement and does not conducting any hot work.
  • Page 4 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information WARNING meter Check that cabling will not be subject to wear, corrosion, excessive 1.00 pressure, vibration, sharp edges or any other adverse environmental 1.00 1312 1.00 effects. The check shall also take into account the effects of aging or 1968 1.00 continual vibration from sources such as compressors or fans.
  • Page 5 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information If H is greater than or equal to 7.22 FT (2.2 M), use Table Value 7.22 FT (2.2 M) If H is under 23.6 IN (0.6 M), use Table Value 23.6 IN (0.6 M) If H is between these values, use the table to calculate A...
  • Page 6 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information Model Nomenclature Brand Brand S – GeoSmart S – GeoSmart Model Model IntelliStart 3 – Eco Y 3 – Eco Y 0 – None 1 – Yes Type Type A – Water to Air A –...
  • Page 7 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information - Serial Plate Example Unit Nomenclature and Serial Number Unit Voltage Fuse/Breaker Size Component Electrical Information Min. distance to combustible surface (in/cm) Max. outlet air temperature )F/C) Unit Restrictions Max. external static pressure (in water/Pa) Max.
  • Page 8 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information Installing Vertical Units Safety Considerations Prior to setting the unit in place, remove and discard the WARNING: Before performing service or compressor hold down shipping bolt located at the front of maintenance operations on a system, turn off main the compressor mounting bracket.
  • Page 9 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information cont. could loosen a single nut. To allow filter access, one Installing Horizontal Units bracket on the filter side should be installed 180° from the Remove and discard the compressor hold down shipping bolt position shown in Figure 3.
  • Page 10 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information cont. Figure 3: Hanger Location and Assembly ISO VIEW Corner #4 Corner #3 Corner #1 Corner #2 Corner post #1 is the post with the water line connections. From a top view, proceed clockwise around the unit for posts 2, 3, and 4.
  • Page 11 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information cont. direction. Tighten the connectors by hand, then gently snug Duct System the fitting with pliers to provide a leak-proof joint. When An air outlet collar is provided on vertical top air discharge connecting to an open loop (ground water) system, thread units and all horizontal units to facilitate a duct connection.
  • Page 12 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE General Installation Information cont. Water Quality Low Water Coil Limit It is the responsibility of the system designer and installing Set the freeze sensing switch SW2-1 on the Aurora Base contractor to ensure that acceptable water quality is present Control (ABC) printed circuit board for applications using and that all applicable codes have been met in these a closed loop antifreeze solution to “LOOP”...
  • Page 13 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Water Quality Material Copper 90/10 Cupronickel 316 Stainless Steel Acidity/Alkalinity 7 - 9 7 - 9 7 - 9 Calcium and (Total Hardness) (Total Hardness) (Total Hardness) Scaling Magnesium Carbonate less than 350 ppm less than 350 ppm less than 350 ppm Less than 0.5 ppm (rotten egg...
  • Page 14 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Hot Water Generator Connections To maximize the benefits of the hot water generator a mini- Figure 11: Typical Hot Water Generator Installation mum 50-gallon water heater is recommended For higher Cold 3/4” x 3/4” x 1/2” tee Water In Water Out demand applications, use an 80-gallon water heater or two...
  • Page 15 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Electrical Connections Pump Power Wiring General Be sure the available power is the same voltage and phase See Figure 14 for electrical connections from control box as that shown on the unit serial plate. Line and low voltage to pumps.
  • Page 16 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Electronic Thermostat Installation Position the thermostat subbase against the wall so that it is level and the thermostat wires protrude through the middle of the subbase. Mark the position of the subbase mount- Figure 15a: Thermostat Wiring (Y1 Style Signals) ing holes and drill holes with a 3/16-inch bit.
  • Page 17 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Blower Performance Data 5-Speed ECM Constant Torque Motors each speed selection. As static pressure increases, airflow decreases resulting in less torque on the rotor. The motor The 5-Speed ECM is a ‘Constant Torque’ ECM motor and responds only to changes in torque and adjusts its speed delivers air flow similar to a PSC but operates as efficiently as accordingly.
  • Page 18 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Vertical Dimensional Data 3 SERIES VERTICAL SUBMITTAL DATA 2 ft [61 cm] Primary Service Access 2 ft [61 cm] Alternate RIGHT RETURN Service Access. Right Return Opposite Side LEFT RETURN 1.90 4.8 1.90 4.8 FRONT Electrical Discharge Connection...
  • Page 19 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Horizontal Dimensional Data TOP VIEW 2.00 5.1 Mount (2) hanger brackets as shown to allow access to filter 2 ft [61 cm] 2 ft [61 cm] Primary Service Access Alternate Service Access Right return opposite side SIDE DISCHARGE VIEW END VIEW FRONT VIEW...
  • Page 20 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Physical Data Dual Capacity Model Compressor (1 each) Copeland Ultra Tech, Dual Capacity Scroll Factory Charge R-454B, oz [kg] Vertical 32 [0.91] 44 [1.25] 58 [1.64] 62 [1.76] *76 [2.15] Factory Charge R-454B, oz [kg] Horizontal 32 [0.91] 42 [1.19]...
  • Page 21 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Reference Calculations Heating Calculations: Cooling Calculations: LWT = EWT + LWT = EWT - gpm x 500 gpm x 500 LAT (DB) = EAT (DB) - LAT = EAT + cfm x 1.08 cfm x 1.08 LC = TC - SC TH = HC + HW...
  • Page 22 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Notes...
  • Page 23 DUAL COMPRESSOR PACKAGED HEAT PUMP INSTALLATION GUIDE Revision Guide Pages: Description: Date: Document Creation 13 May, 2024 Update Altitude description and table 29 July, 2024 Update Physical Data table charge listing 29 July, 2024...
  • Page 24 975 Bleams Road, Unit #1, Kitchener, Ontario N2E 3Z5 | o: 1.866.310.6690 | f: 1.866.533.3889 SMART ENERGY.COM Product: Eco Y Type: Dual Compressor Packaged Heat Pump Size: 2-6 Ton Document Type: Installation Guide Ref. Number: IGW3-0019S *IGW3-0019S* Revision Date: 06\2024 Revision Number: ©2024 The manufacturer has a policy of continual product research and development and reserves the right to change design and specifi...
  • Page 25 MANUEL D’INSTALLATION R-454B / 60Hz IGW3-0019S Informations générales sur l’installation ................2 Nomenclature ........................... 6 Qualité de l’eau ..........................13 Raccords du générateur d’eau chaude ................... 14 Raccords électriques ........................15 Installation du thermostat électronique ................. 16 Données sur le rendement du ventilateur ................17 Données dimensionnelles ......................
  • Page 26 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation AVIS : N’installez pas les unités dans un environnement corrosif Si des travaux à chaud doivent être effectués sur le matériel de réfrigération ou toute pièce associée, un matériel d’extinction ou dans des endroits soumis à...
  • Page 27 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation Espace d’installation requis AVERTISSEMENT Zone ventilée : Assurez-vous que la zone est à découvert ou REMARQUE : Le matériel dont la charge de réfrigérant est infé- qu’elle est correctement ventilée avant d’intervenir dans le rieure à...
  • Page 28 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation Halte AVERTISSEMENT mètres 1,00 Assurez-vous que le câblage ne sera pas soumis à l’usure, à la corrosion, 1,00 à une pression excessive, à des vibrations, à des bords tranchants ou à 1 312 1,00 tout autre effet nocif de l’environnement.
  • Page 29 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation Si H est supérieur ou égal à 2,2 m (7,22 pi), utilisez la valeur du tableau 2,2 m (7,22 pi). Si H est inférieur à 23,6 po (0,6 m), utilisez la valeur du tableau 23,6 pi (0,6 m).
  • Page 30 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation Nomenclature du modèle Brand Brand S – GeoSmart S – GeoSmart Model Model IntelliStart 3 – Eco Y 3 – Eco Y 0 – None 1 – Yes...
  • Page 31 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Renseignements généraux sur l’installation – Exemple de plaque de série Unit Nomenclature and Serial Number Unit Voltage Fuse/Breaker Size Component Electrical Information Min. distance to combustible surface (in/cm) Max. outlet air temperature )F/C) Unit Restrictions Max.
  • Page 32 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation Installation d’unités verticales Considérations de sécurité Avant de mettre l’appareil en place, retirez et jetez le boulon AVERTISSEMENT : Avant d’effectuer toute opération de fixation du compresseur situé à l’avant du support de fixation d’entretien ou de maintenance d’un système, coupez du compresseur.
  • Page 33 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation (suite) requis puisque la vibration pourrait desserrer un écrou simple. Installation d’unités horizontales Pour permettre l’accès au filtre, un support du côté filtre doit être Enlevez et jetez le boulon d’expédition de maintien du compresseur installé...
  • Page 34 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation (suite) Figure 3 : Emplacement et assemblage des crochets ISO VIEW Corner #4 Corner #3 Corner #1 Corner #2 Le poteau cornier n  1 est le poteau doté des raccordements de la conduite d’eau. À partir d’une vue de dessus, faites le tour de l’unité...
  • Page 35 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation (suite) dans la direction souhaitée. Serrez les raccords à la main, puis Système de conduits serrer doucement le raccord avec une pince pour obtenir un joint Un collier de sortie d’air est fourni sur les appareils verticaux étanche.
  • Page 36 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Informations générales sur l’installation (suite) Qualité de l’eau Limite du serpentin de bas niveau d’eau Il incombe au concepteur du système et à l’entrepreneur Réglez le commutateur de détection de gel SW2-1, qui se chargé...
  • Page 37 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Qualité de l’eau Matériel Cuivre 90/10 Cupronickel Acier inoxydable 316 7 - 9 7 - 9 7 - 9 Acidité/Alcalinité Calcium et carbonate (Dureté totale) (Dureté totale) (Dureté totale) Entartrage de magnésium inférieure à...
  • Page 38 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Raccords du générateur d’eau chaude Pour optimiser les avantages du générateur d’eau chaude, Figure 11 : Installation typique d’un générateur d’eau chaude un chauffe-eau d’au moins 189 l (50 gal) est recommandé. Raccord en T de 1,91 x 1,91 x 1,27 cm Entrée Pour les applications à...
  • Page 39 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Raccords électriques Câblage d’alimentation de la pompe Généralités Assurez-vous que l’alimentation disponible correspond au même Voir la Figure 14 pour les connexions électriques entre le boîtier voltage et à la même phase que celles indiquées sur la plaque de commande et les pompes.
  • Page 40 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Installation du thermostat électronique Placez la sous-base du thermostat contre le mur de façon à ce qu’elle soit de niveau et que les fils du thermostat dépassent au milieu de la sous-base. Marquez la position des trous de montage Figure 15a : Câblage du thermostat (signaux de type Y1) de la sous-base et percez les trous avec une mèche de 0,48 cm (3/16 po).
  • Page 41 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Données sur le rendement du ventilateur Moteurs à ECM à 5 vitesses à couple constant la pression statique augmente, le débit d’air diminue, ce qui réduit le couple sur le moteur. Le moteur ne réagit qu’aux changements L’ECM à...
  • Page 42 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Données dimensionnelles verticales 3 SERIES VERTICAL SUBMITTAL DATA 2 ft [61 cm] Primary Service Access 2 ft [61 cm] Alternate RIGHT RETURN Service Access. Right Return Opposite Side LEFT RETURN 1.90 4.8 1.90 4.8 FRONT Raccords électriques...
  • Page 43 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Données dimensionnelles horizontales TOP VIEW 2.00 5.1 Mount (2) hanger brackets as shown to allow access to filter 2 ft [61 cm] 2 ft [61 cm] Primary Service Access Alternate Service Access Right return opposite side SIDE DISCHARGE VIEW END VIEW...
  • Page 44 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Données physiques Capacité double Modèle Compresseur (1 chacun) Copeland Ultra Tech, défi lement à capacité double Charge d’usine R-454B, kg (oz) Verticale 0,91 (32) 1,25 (44) 1,64 (58) 1,76 (62) *2,15 (76) Charge d’usine R-454B, kg (oz) Horizontal 0,91 (32)
  • Page 45 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Calculs de référence Calculs de chauffage Calculs de refroidissement LWT = EWT + LWT = EWT - gmp x 500 gmp x 500 LAT (DB) = EAT (DB) - LAT = EAT + pi3/min x 1,08 pi3/min x 1,08 LC = TC - SC...
  • Page 46 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Notes...
  • Page 47 MANUEL D’INSTALLATION DE LA THERMOPOMPE EMBALLÉE À DEUX COMPRESSEURS Guide de révision Pages  Description  Date  Par  Toutes Création de document 13 mai 2024...
  • Page 48 975 Bleams Road, Unit #1, Kitchener, Ontario N2E 3Z5 | o: 1.866.310.6690 | f: 1.866.533.3889 SMART ENERGY.COM Product: Eco Y Type: Dual Compressor Packaged Heat Pump Size: 2-6 Ton Document Type: Installation Guide Ref. Number: IGW3-0019S *IGW3-0019S* Revision Date: 06\2024 Revision Number: ©2024 The manufacturer has a policy of continual product research and development and reserves the right to change design and specifi...