Télécharger Imprimer la page

VOGELZANG VG5717-P Instructions Du Propriétaire page 7

Publicité

INSTALLATION
OUTSIDE AIR SUPPLY
IN A MOBILE HOME / TRANSPORTABLE BUILDING)
Depending on your location and home construction,
outside air may be necessary for optimal performance.
Your stove is approved to be installed with an outside
air intake (69FAK) which is necessary for a mobile home
/ transportable building. You can purchase the 69FAK
through your heater dealer. Installation instructions are
supplied with the air intake kit.
ATTENTION:
DO NOT VENT UNDER ANY PORCH, DECK, AWNING,
OR IN ANY SEMI ENCLOSED OR ROOFED AREA. DOING
SO MAY RESULT IN UNPREDICTABLE AIRFLOW AT THE
VENT CAP UNDER CERTAIN CONDITIONS AND CAN
AFFECT THE PERFORMANCE OF YOUR STOVE, AS
WELL AS, OTHER UNFORESEEABLE ISSUES.
SECURING APPLIANCE TO THE FLOOR
Use the designated holes to secure the unit to the floor.
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME / TRANSPORTABLE BUILDING FLOOR,
WALL, AND CEILING/ROOF MUST BE MAINTAINED.
WHEN
INSTALLED
TRANSPORTABLE BUILDING, THE STOVE MUST BE
GROUNDED DIRECTLY TO THE STEEL CHASSIS AND
BOLTED TO THE FLOOR.
In addition to the previously detailed installation
requirements, mobile home / transportable building
installations must meet the following requirements:
• This stove must be securely fastened to the floor of the
mobile home / transportable building using two 1/4" lag
bolts that are long enough to go through both a hearth
pad, if used, and the floor of the home.
(OPTIONAL, UNLESS INSTALLING
Exhaust
Pipe
Fresh Air
Intake
IN
A
MOBILE
HOME
• The heater must be electrically grounded to the steel
chassis of the mobile home / transportable building
with 8 GA copper wire using a serrated or star washer
to penetrate paint or protective coating to ensure
grounding.
• Vent must be 3 or 4-inch "PL" Vent and must extend a
minimum or 36" (914 mm) above the roof line of the
mobile home / transportable building and must be
installed using a certified ceiling fire stop and rain cap.
• When moving your mobile home / transportable building,
all exterior venting must be removed while the mobile
home / transportable building is being relocated. After
relocation, all venting must be reinstalled and securely
fastened.
• Outside Air is mandatory for mobile home / transportable
building installation. See Outside Air Supply section and
your dealer for purchasing.
• Check with your local building officials as other codes
may apply.
VENTING REQUIREMENTS
A compatible appliance adapter is required for the proper
venting installation of this unit. Purchase the appropriate
appliance adapter from your preferred venting company
prior to starting the ventilation process.
/
• INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
• DO NOT CONNECT THE PELLET VENT TO A VENT
SERVING ANY OTHER APPLIANCE OR STOVE.
• DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
7
© 2024 United States Stove Company
WARNING:

Publicité

loading