NEVER OPERATE THIS PRODUCT WHILE UNATTENDED
PANEL / REMOTE CONTROLS
The operation of this appliance can be controlled from
the panel located on the side of the stove and/or by the
remote control. The control functions are as follows:
A. On/Off Switch
• When pushed, the stove will automatically ignite. No
other fire starter is necessary. The igniter will stay on
for at least 10 and up to 12 minutes, depending on
when Proof of Fire is reached. The fire should start in
approximately 5 minutes.
• After pushing the "On/Off" button, the auger motor is on
for 3.5 minutes, off for 1 minute. During the remainder
of the start-up period, the auger motor operates on the
heat range "1" setting.
• During start up the heat level advance (Up and Down keys)
will change the heat range indicator level accordingly,
but there is no change in the stoves operating conditions
until start-up is completed.
• During start-up ignition must occur within 12 minutes or
the stove will error out and show E3.
• During the start-up phase, the Mode key does not
function.
B. Heat Range Arrow Buttons
• These buttons when pushed will set the pellet feed
rate, hence the heat output or heat range of your stove.
When using the hand-held remote this function can be
performed with the "Up/Down" buttons.
• The levels of heat output will incrementally change on
the bar graph starting from heat range "1" to heat range
"5".
© 2024 United States Stove Company
OPERATION INSTRUCTIONS
C. °C / °F Button
• The °C / °F button changes the two digit display from
NOTE:
Operation range of this
remote is within 16-1/12 ft.
D. MODE (M/T) BUTTON
of the appliance.
• The Mode of the stove can be switched between manual
• Manual mode operates according to the 5 set levels of
T-Stat mode works as follows:
• The stove has a built in Thermostat into the controls
• Once the stove has gone into run mode the stove can be
• The Up and Down Level / Temp Arrow buttons are used
• Once the stove reaches within 3°F of the desired
• Once the stove reaches the desired set-point, the stove
• When room temperature drops below desired set-point
12
degrees Celsius to degrees Fahrenheit.
and controlled with a Thermostat. Separate LEDs to
the left of the two digit display indicate the mode of
operation – Manual or T-Stat. The stove has to be in
normal operation to be switched from Manual to T-Stat
mode.
feed on the bar graph from heat range "1" to heat range
"5".
of the appliance. The temperature sensor for the T-Stat
is located on the back of the stove behind the display
board.
switch into T-Stat mode.
to change the desired set-point temperature. Once the
desired temperature is reached the two digit display
will flash for four seconds and reset to the actual room
temperature.
temperature set point, it returns to the heat range that
the stove was set on before it was switched to T-Stat
mode (if the stove was running on heat range "5" when
switched to T-stat mode when it gets within 3°F of the
set point it will return to heat range "5").
will drop to heat range "1".
the stove will ramp back up until it reaches the desired
temperature.