AC OUTPUT PROTECTION
Protection
Problem
Overload
No AC output
protection
while DC output
can work normally.
Short circuit
The power station
protection
shuts down. No
output from any
ports. No display
on LCD screen.
NOTE: If the AC output does not detect a connected
device for 6 hours (a device which draws less than
10 W cannot be detected), the AC circuit will switch
off automatically. Press the AC output switch again to
reactivate the AC circuit.
POWERING DC DEVICES
The power station can also power a 12V DC device such
as DC fans and LED lights. Press the DC output switch to
activate DC power, and connect the appliance to the DC
recepticle of the power station. The LCD screen will light up
and show the output (Fig. 8).
Fig. 8
LCD Screen (DC
discharging mode)
DC OUTPUT PROTECTION: If the DC output is shorted
or overloaded, the device will shut down for protection.
Check the table below for details.
DC OUTPUT PROTECTION
Protection
Problem
Overload
No DC or USB
protection
output while AC
output can work
normally.
Short circuit
The device shuts
protection
down. No output
from any ports. No
display on LCD
screen.
Solution
Remove the extra load
and press the AC output
switch again to recover.
Remove the device
causing the short circuit.
Press the power switch
and the AC output
switch again to recover.
DC output
switch
Solution
Remove the extra load
and press the DC output
switch again to recover.
Remove the device that
caused the short circuit.
Press the power switch
and the DC output
switch again to recover.
NOTE: The DC output voltage will decrease as the battery
capacity decreases, which may cause the connected DC
device to shut down or to suspend charging.
NOTE: If the DC output doesn't detect a connected
device for more than 2 hours (an output less than 2 W
is considered not detectable), the DC circuit will switch
off automatically. Press the DC output switch again to
reactivate the DC circuit.
POWERING USB DEVICES
To power USB devices, press the DC output switch to activate
power to the USB ports. Then connect your USB cable into
either the USB-C port or into either of the USB-A ports on the
power station to charge your device (Fig. 9).
LCD Screen (USB
discharging mode)
USB OUTPUT PROTECTION:
USB OUTPUT PROTECTION
Protection
Problem
Overload
The overloaded
protection
USB port(s) will
have no output.
Other receptacles
can work normally.
Short circuit
The short-circuited
protection
USB receptacle(s)
will have no
output. Other
receptacles can
work normally.
7
DC output
switch
Fig. 9
Solution
Remove the extra load
from the receptacle(s).
Remove the device from