VIKING MODEL VEDV900
EXTERIOR MOUNTED BLOWER
FOR USE WITH VIKING MODEL VIPR101, VIPR161, VIPR181, VIPR101R, VIPR161R AND
VIPR181R DOWNDRAFT VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done
by a qualified person(s) in accordance with all
applicable codes and standards, including fire-
rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guide-
line and safety standards such as those published
by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
PLAN THE
INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the
length of the duct run and
number of elbows needed
are kept to a minimum.
2. Where possible, blower
should be centered between
wall studs or roof rafters.
3. Avoid pipes, wires, or other
ductwork that may be run-
ning through the wall.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL VEDV900
EXTERIOR BLOWER
10" ROUND
TO
DOWNDRAFT
TYPICAL ROOF MOUNTED INSTALLATION
1
WARNING
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the out-
doors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to ex-
haust hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
4. Electrical circuit, including speed control, (if used),
must be rated 6 AMPS minimum.
Blower Dimensions
28.25 x 24.75 x 7.17
SPECIFICATIONS
MODEL
VOLTS
VEDV900
120
DUCT
AMPS
CFM
DUCT SIZE
5.7
900
10 " DIA.
10" ROUND DUCT
TO
DOWNDRAFT
TYPICAL
WALL MOUNTED INSTALLATION
MODEL
VEDV900
EXTERIOR
BLOWER

Publicité

loading

Sommaire des Matières pour Viking VEDV900

  • Page 1 VIKING MODEL VEDV900 EXTERIOR MOUNTED BLOWER FOR USE WITH VIKING MODEL VIPR101, VIPR161, VIPR181, VIPR101R, VIPR161R AND VIPR181R DOWNDRAFT VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC 5. When cutting or drilling into wall, or ceiling, do not SHOCK, OR INJURY TO PERSONS, OBSERVE damage electrical wiring or other hidden utilities.
  • Page 2 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 1. Locate the blower on the rear slope of the roof. 1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the Place it in a location to minimize duct run.
  • Page 3 INSTALL THE BLOWER INSTALL THE BLOWER ROOF INSTALLATIONS WALL INSTALLATIONS 1. Remove roofing nails from the upper 2/3 of the 1. Place a large bead of caulk on the back side of the shingles around the cutout area and carefully lift the housing along the outer edge.
  • Page 4 Be careful not to bend or otherwise damage blower wheel. NOTE: Use duct tape to make ductwork connections secure and air tight. MOTOR LUBRICATION The motor is permanently lubricated. Do not oil or disassemble motor. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99042942D...
  • Page 5 VIKING MODÈLE VEDV900 VENTILATEUR MONTÉ À L’EXTÉRIEUR POUR UTILISATION AVEC LES VENTILATEURS à TIRAGE VERS LE BAS VIKING – MODÈLES VIPR101, VIPR161, VIPR181, VIPR101R, VIPR161R ET VIPR181R VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER AVERTISSEMENT AVERTISSEMENT 6. Les ventilateurs canalisés doivent toujours être ventilés OBSERVEZ LES DIRECTIVES CI-DESSOUS DE à...
  • Page 6 PRÉPARATION DE PRÉPARATION DE L’EMPLACEMENT DE POSE L’EMPLACEMENT DE POSE POSES SUR LES TOITS POSES SUR LES MURS 1. Choisissez un emplacement de pose pour le ventilateur 1. Choisissez un emplacement sur le mur extérieur. sur la pente arrière du toit. Placez-le dans un emplacement Assurez-vous qu’aucun poteau mural, tuyau ou câble réduisant au maximum l’utilisation de conduits.
  • Page 7 POSE DU VENTILATEUR POSE DU VENTILATEUR POSES SUR LES TOITS POSES SUR LES MURS 1. Retirez les premiers deux tiers des clous à toiture des 1. Appliquez une large bande de produit à calfeutrer à bardeaux se trouvant autour de la surface de découpe l’arrière du boîtier, le long du rebord extérieur.
  • Page 8 Le moteur est lubrifié en permanence. Il ne doit pas être huilé ni démonté. REMARQUE : Utilisez du ruban pour canalisations pour fixer solidement tous les raccords des conduits et les étancher. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99042942D...