PROBLEM
Air leak from
Possible defect in safety
safety valve.
valve.
Pressure reading
It is normal for "some"
on the regulated
pressure drop to occur.
pressure gauge
drops when an
accessory is
used.
Compressor is not
Prolonged excessive use of
supplying enough
air.
air to operate
Compressor is not large
accessories.
enough for air requirement.
Hole in hose.
Air leaks.
Excessive "auto"
Condensation in tank
starting and
stopping
All manuals and user guides at all-guides.com
8/1/06
10:14 AM
Page 16
CAUSE
Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.
If there is an excessive
amount of pressure drop
when the accessory is used,
adjust the regulator following
the instructions in the
"Description of Operation"
paragraph in the "Operation
Section.
NOTE: Adjust the regulated
pressure under flow
conditions (while accessory is
being used).
Decrease amount of air
usage.
Check the accessory air
requirement. If it is higher
than the SCFM or pressure
supplied by your air
compressor, you need a
larger compressor.
Check and replace if
required.
Tighten fittings.
Drain tank
16