User manual
1.4 INSTALLATION
The unit should be mounted by its screws holes on the bracket. Always ensure that th eunit is frimly fixed
to avoid vibration and slipping while operating. The structure to which you are attaching the unit should
be able to support 10 times the weight of the unit. Also always use a safety cable than can hold 12 times
the weight of the unti when installing the fixture. The quipment must be fixed by professionals.
1.4 SPECIAL CONSTRUCTION FOR DMX CONNECTION
At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors. Solder a
120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the
DMX-output of the last fixture.
If the controller is 5-pin output, it's necessary to use an adaptor to transfer signal from 5-pin output
to 3-pin XLR-plug or you can connect cables as following:
2. TECHNICAL SPECIFICATIONS
6 x 20 W COB LED PAR RGB FC
* Light Source : 9 x 8 W LED RGBW 4 in 1
* 6 700 LUX@1M
* Noise : Quiet (0dBA)
* DMX modes : 3/5/7
* Control modes : DMX, Master-Slave, Auto, Sound active
* Beam angle : 80°
* Dimming : 0-100%
* Strobe
* Frequency : 50/60Hz
* Voltage : AC100-240V, 50/60Hz
• Power consumption : 115W
* Dimensions: 287×250×126 mm
* Net weight 4,5Kg
PAR COB 620
9