Se ng the ON/OFF TIMES
:
12h/12h
Slide the Switch to 12h/12h to set the ON-
Time to 12 hours and the OFF-Time to 12
hours
18h/6h :
Slide the Switch to 18h/6h to set the ON-
Time to 18 hours and the OFF-Time to 6
hours.
Rese ng the ON-Cycle (Day Cycle)
Reset Cycle :
Slide and hold the selector in MIDDLE POSITION to start a new
ON-cycle (i.e. to start the beginning of a new day cycle). Once the
RESET is completed, select either 18h/6h or 12h/12h. Should you
forget the selector in the RESET posi on, the mer will use the
most previous me se ng (18h/6h or 12h/12h, as selected be-
fore rese ng the ON-cycle).
STATUS Indicator during Normal Opera on
HOT START: 1 short BLINK every 3 seconds
Indicates the controller has returned from a power outage and is now coun ng down
the 20-min delay to prevent Hot Start. Delay can be stopped by switching to RESET
momentarily and then switching back to 18h/6h or 12h/12h.
PULSE:
Indicates the remaining me (number of hours le in the
current ON or OFF-cycle). See details in the box on the next page.
STATUS Indicator while Rese ng an ON-Cycle
SLOW FLASHING:
Indicates the 30-second countdown before RESET. If Slide Switch is returned
to either 12h/12h or 18h/6h before the end of the 30-second countdown,
the RESET will NOT occur.
STEADY:
Indicates the RESET has been completed and a new ON-cycle has just started.
User must select the ON/OFF Times by sliding the switch to either 12h/12h or 18h/6h.
QUICK FLASHING
Warning! ON/OFF TIMES selec on has not been completed. The selector has been
forgo en in RESET posi on. Select either 18h/6h or 12h/12h.
STATUS Indicator OFF
See TROUBLESHOOTING sec on on the next page.