Fitted units
•
This appliance is only intended to be fully fitted in a kitchen .
•
This appliance is not designed to be used as a tabletop appliance or inside a cupboard.
•
The fitted cabinet must not have a back wall behind the appliance.
A gap of at least 35 mm must be maintain between the wall and the base or back panel of the
•
unit above.
•
The fitted cabinet must have a ventilation opening of 250 cm
back the base panel or fit a ventilation grille.
•
Ventilation slots and intakes must not be covered .
•
The safe operation of this appliance can only be guaranteed if it has been installed in
accordance with these installation instructions.
•
The fitter is liable for any damage resulting from incorrect installation.
•
The units into which the appliance is fitted must be heat-resistant up to 90 °C.
Installation dimensions
Ventilation openings
behind, min. 250 cm
2
min.
Back
panels
open
Ventilation area in the
base min. 250 cm
2
Note: There should be gap above the oven.
Building in
• Do not hold or carry the appliance by the door handle. The door handle cannot hold the
weight of the appliance and may break off.
1. Carefully push the oven into the box, making sure that it is in the centre.
2. Open the door and fasten the oven with the screws that were supplied.
min 35
Ventilation grid
Cupboard feet
41
on the front. To achieve this cut
2
min 35
460
Ventilation in the
base min. 250 cm
min.
50
Back
panel
open
2