Télécharger Imprimer la page

DeWalt DCE592 Guide D'utilisation page 13

Publicité

To Remove
1. Firmly pull the sun shade
motor housing
.
3
Connecting a Lifting Strap (Fig. A, P–S)

WARNING: Lifting straps used must be compliant
with ASME B30.9. Lifting Hooks must be
compliant with ASME B30.10. Rigging Hardware
must be compliant with ASME B30.26.
nOTE: User is responsible for sourcing proper lifting strap
accessory (sold separately) for use with your tool.
Locate the four strap latches
1. Secure each of the clips
strap
into the four strap latches
19
nOTE: You must connect the lifting strap
of the four strap latches
latches 
depending upon the lifting orientation
 5
(see Fig. P–S).
2. Ensure the lifting straps are not twisted or kinked
before lifting.
3. Straps must be equal length and with equal tension on
them when lifting.
LED Screen (Fig. F–I)
The DCE592 is equiped with a multicolor LED screen 
The LED screen
displays units of pressure, state of battery
6
charge, and state of pressure lights.
Mode button
(Fig. A–F)
7
1. Press the mode button
measurement is set to PSI or bar.
Vacuum indicators
18
When the vacuum button
indicators
will illuminate green.
18
1. Slide the on/off power switch
The DCE592 is now on, and the LED screen
shows 0 PSI/bar and no lights.
2. After placing on clean surface of load to be lifted, press
the vacuum button
8
activate and pressure will begin to build to -12 PSI
(-0.83 bar). Four green lights illuminate in sequence
on the LED screen 
 6 
maximum level.
3. The LED screen 
 6 
displays the pressure in units of bar or PSI
depending on the mode button. The vacuum pump stops
running when the pressure reaches -12 PSI (-0.83 bar) .
4. If vacuum pressure falls below -10.4 PSI (-0.72 bar), the
vacuum pump will automatically activate to restore
vacuum pressure to -12 PSI (-0.83 bar).
5. If the material is too porous to achieve -12 PSI (-0.83 bar)
vacuum pressure, the vacuum pump will run continuously.

WARNING: Use extreme caution when lifting in
this case because lifting capability is reduced.
6. The release button
9
are electronically disabled while the vacuum pump
is enabled.
up and away from the
17
5
around the lifter body
at the ends of the lifting
20
.
5
to each
19
. Or just two of the strap
5
7
to switch until the unit
display green (Fig. F–i)
8
is activated, the four vacuum
2
to the ON position.
6
display
once. The vacuum pump will
as the pressure builds to
and the on/off power switch 
Vacuum indicators
When the vacuum button
indicators
18
1. To release the load, deactivate vacuum pump by pressing
the vacuum button
illuminate red and blink rapidly.
2. Slide trigger lock button
the release button
release the load.
3. The four vacuum indicators
19
sequence as the pressure drops.
lED screen flashing and low battery chime (Fig. i)
4
.
1. The low battery chime will sound and the LED screen 
will flash to indicate a low battery condition.

WARNING: When the low battery chime sounds and
the LED screen
set down the load being carried and secure it in place
or risk the lifter releasing the load prematurely which
may result in serious personal injury and damage to
the material being lifted. Once down, press the vacuum
button
lock button
the release button
pressure and release the load. Replace or charge the
battery. The DCE592 will not allow a lift to begin if the
.
 6 
battery state of charge is below 20%.
2. An alert chime will sound if the vacuum pressure falls
below -11.7 PSI (-0.81 bar) even if battery is fully charged.
nOTE: This may happen below -11.7 PSI (-0.81 bar) on
porous materials.
3. If pressure is falling the user must immediately set down
the load being carried and secure it in place. If pressure is
falling, the user should replace the foam rubber seal 
or reposition the tool to a nonporous section of
the material.
state of charge indicator (Fig. h, i)
The DCE592 is equipped with a state of charge indicator. This
will display the current level of charge in the battery during
use. It does not indicate tool functionality and is subject to
variation based on product components, temperature and
end-user application.
The state of charge indicator LEDs 
indicating the percent of charge in the battery.
When all three state of charge indicator LEDs 
illuminate, the battery is fully charged.
When one state of charge indicator LEDs 
charge is low and then it will flash red when the battery
is discharged. Remove the battery and charge it.
State of Charge Indicator Status
 2 
display red (Fig. F–i)
18
8
is deactivated, the vacuum
will illuminate red and blink.
8
. The vacuum indicators
forward and press and hold
10
9
to vent the vacuum pressure and
will stop illuminating in
18
 6 
flashes, the user must immediately
8
to deactivate vacuum pump, slide the trigger
10
forward and then press and hold
9
to vent the remaining vacuum
LEVEL OF CHARGE
100% - 75%
50% - 75%
10% - 50%
10% or less.
Red and LED screen flashing.
Low battery shutdown
English
18
will
 6 
 12 
 25 
will illuminate,
 25 
 25 
illuminates,
CHARGE INDICATOR
LED COLOR
Yellow
Yellow
Red
11