Truck will not travel, nor
will lift system operate.
Truck does not travel
forward or in reverse. All
other functions operate
normally.
Truck travels forward,
but not in reverse.
Truck travels in reverse,
but not forward.
Truck travels forward
and in reverse at lower
speeds; will not travel at
high speed.
Truck does not slow with
brake, or brake does not
engage.
Brake will not release.
PAGE 1 OF 9
1-800-295-5510
uline.com
TROUBLESHOOTING
PROBABLE CAUSES
Fuse blown.
Battery dead or disconnected.
Key switch defective.
Defective wiring.
Check all wiring. A loose
connection may be the cause
of malfunction.
Defective deadman switch.
Defective controller.
Defective potentiometer.
Defective potentiometer.
Defective deadman switch.
Defective electric brake.
Brake temperature above 281° F.
Open brake circuitry or wiring.
Air gap more than 0.01" (0.25 mm)
(only for H-4710).
Pour le français, consulter les pages 9-13
RECOMMENDATIONS
Check fuse and replace if necessary.
Check battery connections and battery
voltage.
Bypass key switch to determine if it is
malfunctioning.
Check for open circuit. Repair as required.
Tighten all loose connections before further
troubleshooting.
Check and replace switch if defective.
Check for proper operation and replace if
defective.
Check and replace potentiometer if defective.
Check and replace potentiometer if defective.
Check deadman switch for continuity. If none
found when the control arm is in the brake
position, replace switch.
Replace brake.
Allow to cool.
Make voltage checks.
Adjust air gap.