Hints for test centres
Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse
aid dispenser.
Test standard
Reference programme:
Load:
Rinse aid selector:
Detergent dosage :
US65
Arrangement
upper basket
Technical specifications
DIMENSIONS
ELECTRICAL CONNECTION
MOTOR RATING DURING WASH
POWER OF HEATING ELEMENT
OVERALL POWER
WATER SUPPLY PRESSURE
CAPACITY
All manuals and user guides at all-guides.com
EN 50242
BIO 50°C
9 standard place settings
position 4
20 g in the dispenser
5 g on the dispenser lid
UI51
Width
Height
Max depth
Max depth with open door
Voltage
Minimum
Maximum
58
Arrangement
lower basket
44.6 cm
81.8 - 87.8 cm
57.5 cm
111.4 cm
230 V - 50 Hz
200 W
2100 W
2300 W
50 kPa (0.5 bar)
800 kPa (8 bar)
9 place settings
IST09en