Télécharger Imprimer la page

Portfolio Outdoor Dual Brite PF-4291-BK Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

❒ Walk through the coverage area noting
where you are when the lights turn on.
Move the sensor head left or right to
change the coverage area.
IMPORTANT: Grasp the sensor only as
shown and turn the entire sensor. Any
other method may damage the sensor.
Do not force the sensor past the stop-
ping points.
Rotating Sensor Head to Change
Coverage Area
❒ If you need to change the sensitivity,
temporarily remove the fixture and make
the adjustment. Too much sensitivity may
increase false triggering.
❒ Set the amount of TIME you want the light
to stay on after motion is detected. (1, 5,
or 10 minutes).
❒ Set the amount of time after dusk you want
the lights on accent level.
All manuals and user guides at all-guides.com
6
BULB REPLACEMENT
If lantern has an open bottom, insert bulb
through opening and screw into socket.
If lantern has a closed
bottom, follow the steps
below to replace bulb.
1. Model 4294 Only -
Remove the lower
arm by removing
the two decorative
screws attaching
the lower arm to
the canopy and
lower glass as-
sembly.
2. Place one hand
under lower glass
assembly and un-
screw decorative
screws
holding
lower glass as-
sembly to top of fixture.
3. Replace bulb.
4. Reattach lower glass assembly to fix-
ture top using decorative screws.
SPECIFICATIONS
Range ................... Up to 30 ft. (9.1 m) [var-
ies with surrounding
temperature].
Sensing Angle ...... Up to 150°
Electrical Load ...... Up to 100 Watt Maximum
Tungsten Incandescent.
Sensor Capacity ... Up to 360 Watt (3.0 A.)
Maximum Tungsten In-
candescent.
Power
Requirements ....... 120 VAC, 60 Hz
Operating Modes .. TEST, AUTO, and MAN-
UAL MODE
Time Delay ........... 1, 5, 10 minutes
D
B
Timer .. 3, 6 hrs, Dusk-to-Dawn
®
ual
rite
Decorative Screws
Light
Bulb
Lower Glass
Assembly
598-1234-04

Publicité

loading