Télécharger Imprimer la page

Enerco Mr. Heater MHU 45 Instructions D'utilisation Et Manuel Du Propriétaire page 15

Publicité

ELECTRICAL
1.
Check all wiring for loose connections.
2.
Check for correct voltage at unit (unit operating).
3.
Check amperage draw.
FLUE AND CHIMNEY
Check all vent and vent connector joints for tightness. ensure that
connections are sealed and that there are no blockages.
FAILURE TO OpERATE
If unit fails to operate check the following:
1.
Is thermostat calling for heat?
2.
Is main disconnect closed?
3.
Is there a breaker tripped or a fuse blown?
4.
Is gas turned on at meter?
5.
Is manual shutoff valve open?
6.
Is unit ignition system in lock out? If unit locks out again, call
service technician to inspect unit.
7.
Is pressure switch closed? obstructed flue will cause unit to
shut off at pressure switch. Check flue passage and outlet.
REpAIR pARTS
When ordering repair parts include the complete unit model
number listed on the unit rating plate. For example: MHU45/75
and HSU45/75.