E2 LCD 600/800: UPS unit with integrated input cable, 2 IEC output cables, 1 RJ11 cable, 1
USB cable, and a user guide.
E2 LCD 1000: UPS unit, 2 IEC output cables, 1 RJ11 cable, 1 USB cable, and a user guide.
E2 LCD 1500/2000: UPS unit, 3 IEC output cables, 1 RJ11 cable, 1 USB cable, and a user
guide.
In the event of damage, please submit a standard claim to the after-sales service
department.
2. Charging the batteries
This unit is shipped from the factory with its internal battery fully charged, however, some
charge may be lost during shipping and the battery should be recharged prior to use. Plug
the unit into an appropriate power supply and allow the UPS to charge fully by leaving it
plugged-in, with no load, for at least 8 hours.
The UPS will automatically recharge its own batteries as soon as it is connected to the
mains. You may use the UPS immediately, however the back-up power capacity may be
lower than the nominal value required.
3. Placement & storage conditions
The UPS has been designed to operate in a protected environment, at temperatures
between 0°C and 40°C and at a humidity level ranging between 0% and 90% (no
condensation).
Do not obstruct the ventilation slots. Install the unit in an environment which is free from
dust, chemical vapours and conductors. Moreover, in order to avoid any interference, keep
the UPS at least 20cm away from the CPU (central processing unit).
4. Connection & charging
Check the identification plate at the back of the UPS to make sure that the power supply is
compatible with network voltage and that the device is powerful enough to protect the given
load. Plug the UPS into a 2-pole, earthed outlet (use the original power cable of your
computer or it is recommended to use a 2P+E/CEE22/10A power cable. Then, use IEC
cables to connect computer-related devices to the back of the UPS. For best results, it is
recommended to charge the battery at least 4 hours before initial use of models up to 800
VA and at least 6 hours for 1000 up to 2000 VA models. The UPS charges its battery as far
as it is connected to the mains even if the UPS is off. 600 & 800 VA models are equipped
with a 3-stage charger to optimize battery performance. 1000 VA model and higher are
equipped with a super smart charger that allows 90% battery charge within only 4 hours.
5. On/Off
To turn the UPS unit on, lightly press the power switch. To turn it off, press the power switch
again. Make sure that the power switch is kept in the "ON" position, otherwise the UPS will
be disabled and your equipment unprotected in the event of power failure.
Note: For maintenance purposes, please turn the UPS on before the PC and other loads,
and turn it off after the connected loads are turned off.
6. DC Start
E2 LCD units are equipped with an integrated DC start function. To start the UPS in the
absence of a power supply and with a full battery, simply press the button.
7. Power Saving Function
E2 LCD UPS range features a green technology switch mode charger that allows to charge
its battery very fastly & generates 50% energy saving compared to a classic UPS. This
range is also is equipped with a Power Saving Function. If no load connects to the UPS, it
will automatically shut down after 5 minutes to save energy during a power failure. The
Power switch must be kept in the 'ON' position, otherwise the UPS will be disabled and your
equipment will not be protected during a power failure.
INFOSEC UPS SYSTEM - 4, rue de la Rigotière - 44700 Orvault - FRANCE - www.infosec-ups.com
8
Hot Line – Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 08 12 AA 59 205 19