MODEL: PST9032
WARNING:
!
Use only those fasteners recommended
for use with this tool. Fasteners not
identified for use with this tool by the tool
manufacturer are able to result in a risk of
injury to persons or tool damage when
used in this tool.
WARNING:
!
Keep the tool pointed away from yourself
and others when loading fasteners.
Failure to do so could result in possible
serious personal injury.
WARNING:
!
Never load fasteners with the workpiece
contact or trigger activated. Doing so
could result in possible serious personal
injury.
UNLOADING FASTENERS
Unloading is the reverse of loading. Always
disconnect the air source before unloading.
WARNING:
!
Always unload all fasteners before removing
tool from service.
WARNING:
!
Always disconnect the air source before
unloading.
CLEARING JAMS
Occasionally, a fastener may become jammed in
the firing mechanism of the tool, making the tool
inoperable. To remove a jammed fastener, follow
the steps below:
1.
Disconnect the tool from air source.
2.
Remove fasteners from the tool. Failure to do
so will cause the fasteners to eject from the front
of the tool.
⒊
Completely remove the small nose screws(E)
and the top nose plate(F) to reveal the jammed
fastener.
⒋
Using caution not to bend or damage the driver
blade, using pliers or a screwdriver if required to
clear the jammed fastener.
⒌
Put the nose plate(F) back on the nose(G),
fastening it with the screws(E).
⒍
Reconnect the tool to the air source.
⒎
Reload the tool with fasteners.
08
.
HTTP://WWW FREEMANTOOLS COM
Nose(G)
Nose plate(F)
Nose screws(E)
WARNING:
!
Make sure there is no fastener in
magazine before clearing a jam.
WARNING:
!
Disconnect the tool from the air source
whenever clearing a jam. After
disconnecting the tool from the air
compressor, there should still be enough
air pressure to fire the tool. After the air
hose is disconnected, always fire the tool
into scrap wood repeatedly to make sure
all of the compressed air is expended.
NO-MARRING PAD
The non-marring pad attached to the nose of the
tool helps prevent marring and denting when
working with softer woods.
WARNING:
!
Disconnect the tool from the air resource
before removing or replacing the non-
marring pad. Failure to do so could result
in serious personal injury.
.
1-888-669-5672
MODEL: PST9032
SETTING THE AIR PRESSURE
The amount of air pressure required depends on
the size of the fasteners and the workpiece material.
Begin testing the depth of drive by driving a test nail
into the same type of workpiece material used for
the actual job.Drive a test fastener with the air
pressure set at 90-95psi. Raise or lower the air
pressure to find the lowest setting that will perform
the job with consistent results.
It may be possible to achieve the desired depth with
air pressure adjustments alone.
FIRING THE TOOL
This mode requires the trigger to be pulled each
time a fastener is driven. The tool can be actuated
by depressing the WCE against the work surface
followed pulling the trigger.
The trigger must be released to reset the tool before
another fastener can be driven.
WARNING:
!
Always know the operational mode of the
tool before using. Failure to know the
operational mode could result in death or
serious personal injury.
WARNING:
!
An improperly functioning tool must not
be used. Do not actuate the tool unless the
tool is placed firmly against the work
place.
.
HTTP://WWW FREEMANTOOLS COM
WORK CONTACT ELEMENT (WCE)
Disconnect the air supply from the tool.
⒈
Remove all fasteners from the magazine.
⒉
⒊
Make sure the trigger and work contact element
move freely up and down without sticking or
binding.
Reconnect air supply to the tool.
⒋
Depress the work contact element against the
⒌
work surface without pulling the trigger. The tool
must not operate. Do not use the tool if it
operates without pulling the trigger. Personal
injury may result.
⒍
Remove the tool from the work surface. The
work contact element (WCE) must return to its
original down position. The tool must not
operate. Do not use the tool if it operates while
lifted from the work surface. Personal injury may
result.
Pull the trigger and depress the work contact
⒎
element(WCE) against the work surface. The
tool must not operate.
Depress the work contact element (WCE)
⒏
against the surface. Pull the trigger. The tool
must operate.
CAUTION:
Check the operation of the work contact
element trip mechanism before each use.
The WCE must move freely without
binding through its entire travel distance.
The WCE spring must return the WCE to
its fully extended position after being
depressed. Do not operate the tool if the
WCE trip mechanism is not operating
properly. Personal injury may occur.
MAINTENANCE
WARNING:
!
Any time inspection, maintenance, and
cleaning are done:
◆
Disconnect the tool from the air resource.
◆
Empty the magazine completely.
-
ANTI DUST
Each tool is packed with an anti-dust cap on the air
connector.
Keep the anti-dust cap cover on the air connector
when the tool is not in use.
.
1-888-669-5672