MAKING TERMINAL BLOCK CONNECTIONS
CAUTION: Use a multimeter to confirm wire polarity before making
!
connnections or damage to equipment may occur.
ATTENTION: Utiliser un multimètre pour confirmer la polarité des
!
fils avant d'effectuer la connexion ou des dommages à l'équipement
peut se produire.
1. Strip 1/4" of insulation from wire ends. (FIGURE A)
2. Determine correct polarity of positive + and negative -
wire ends.
3. Select appropriate color-coded terminal block:
A. Orange = 5V DC
B. Yellow = 12V DC
C. Blue = 18V DC
D. Red = 24V DC
4. Insert bare wire ends into terminal block.
5. Tighten connections securely with screwdriver.
6. Insert terminal block into appropriate power bank.
RACK EAR INSTALLATION
1. Install rack ears as shown using supplied rack ear screws. (FIGURE B)
NOTE: The longer rack ear (E or G)
is installed on the side containing
the IEC socket.
2. Rack ears may be installed in a variety of orientations. For more information, see Rack Ear Mounting
Orientation on page 8.
1/4"
+
E or G
FIGURE B
Page 7
+
-
FIGURE A
-
F or H
J