Télécharger Imprimer la page

Middle Atlantic Products PD-DC-125R Manuel D'instructions page 6

Publicité

CONNECTIONS, CONTROLS AND INDICATORS
FRONT VIEW
REAR VIEW
B
TOTAL 5V 2.5A
(ALL USB)
G
SIDE VIEW
DESCRIPTION
A. 15A CIRCUIT BREAKER POWER SWITCH
B. USB POWER BANK 2.5A TOTAL (FOUR OUTPUTS)
C 5V DC 3A BANK (SIX OUTPUTS): Individually protected by automatically resettable
PTC Fuses. Short circuit and overload protection.
D. 12V DC 2A BANK (SIX OUTPUTS): Individually protected by automatically resettable
PTC Fuses. Short circuit and overload protection.
E 18V DC 2.5A BANK (SIX OUTPUTS): Individually protected by automatically resettable
PTC Fuses. Short circuit and overload protection.
F. 24V DC 1.2A BANK (SIX OUTPUTS): Individually protected by automatically resettable
PTC Fuses. Short circuit and overload protection.
G. BANK OVER CURRENT WARNING LIGHT: Green = OK. Amber = Approaching current limit of
power bank, shutdown imminent.
H. IEC C-14 POWER INPUT: 120VAC, 5A 60HZ
J. OUTPUT POWER INDICATOR LED (ONE PER EACH OUTPUT CONNECTOR):
Green = OK. Off = No power.
C
D
G
E
PD-DC-125R
STATUS
ACTIVE
OVERLOAD
SHUTDOWN
G
120V 5A 60Hz
H
Page 6
A
POWER
I
B
F
G
J

Publicité