Fig. 1: Device front
230 V consumer output (pos. 1)
The 230 V output is for supplying the 230 V consumers. A 230 V distribution
box may be needed here.
230 V input (pos. 2)
The 230 V input is connected to the 230 V input protection. The power is
supplied from here through the mains or by a generator.
Operating check light (pos. 4)
The operating check light (green) shows if there is 230 V on the output. It
lights up when the 230 V output is ready. The light goes off, when the mains
protector of the 230V output has switched off or the test button has been
actuated.
Test button (pos. 3)
The test button (red) simulates a voltage spike on the mains protector. In this
way the correct functioning of the mains protector can be checked. The button
is actuated for a short time to carry out a functional test. Hereupon the mains
protector switches off the 230 V output for a short time and the operating
check light goes out. The operating check light lights up again once the mains
protector enables the output again. Carry out this functional test once a month
and always after a short circuit occurs or is thought to have done so.
! " # $
Lerchenfeldstr. 9 87600 Kaufbeuren Tel.: +49(0)8341 / 9764-0 Fax: +49(0)8341 / 67806
Connections and operating
elements
1 = 230 V consumer output
2 = 230 V input
3 = Test button
4 = Operating check light
%&