Safety distances
The heater must be installed at a minimum height of 180
-
cm.
If installed in a toilet, the height should be 225 cm in zone
-
1 and zone 2; in zone 3 the minimum above ground level
is 180 cm, according with the rules of each Country.
-
A minimum air gap of 30 cm should always be allowed
between the top of the heater and a ceiling or roof. The
appliance should be 50 cm far from the walls
30cm
180cm
-
The heater must not be directed towards the ceiling or
flammable materials.
The device must not be mounted into the ceiling. You
-
must leave enough space around the top of the unit to
ensure good ventilation.
Do not use the heater in close proximity of a bath, shower
-
or swimming pool.
-
If there is nobody in the room to be heated, it is
recommended to turn off the unit.
50cm
27
50cm
www.bsvillage.com