H-1200 CARTRIDGE - PART NO. EV9282-01, EV9282-03,
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a water
IMPORTANT NOTICE: Read this Performance Data Sheet and
compare the capabilities of this unit with your actual water
treatment needs. It is recommended that, before purchasing a
water treatment unit, you have your water tested to determine
your actual treatment needs.
FEATURES
• Finely polishes treated water to premium quality for drinking
and cooking.
• NSF/ANSI Standard 53 certified to reduce cysts such as
Cryptosporidium and Giardia by mechanical means.
• IAPMO R&T certified against NSF/ANSI 53 for the reduction
of Total PFAS.
• High-performance system certified to reduce up to 99.6% of
Total PFAS, commonly known as "forever chemicals".
• Reduces dirt, rust and other particulates sulfides (oxidized
iron and manganese – As tested by Everpure).
• Controls even extreme levels of common "off" taste and
odors, including those which are earthy, moldy, and fishy.
• Reduces lead to below the Federal Action Level of 15 ppb.
• Effectively reduces methyl tertiary-butyl ether (MTBE).
• Reduces particles as small as 0.5 micron in size by
mechanical means.
H-1200 Performance Data*
This system has been tested according to NSF/ANSI 42, 53, and
401 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified
in NSF/ANSI 42, 53, and 401.
PERFORMANCE DATA SHEET
H-1200 DRINKING WATER SYSTEMS
OPERATING SPECIFICATIONS
• Capacity: 1,000 gallons (3,785L)
• Pressure Requirement: 10-125 psi (0.7 - 8.6 bar), non-shock
• Temperature: 35-100°F (2°-38°C)
• Flow Rate: 0.5 gpm (1.9 Lpm)
PERFORMANCE DATA SHEET REDUCTION CLAIMS FOR
ORGANIC CHEMICALS INCLUDED BY SURROGATE TESTING
NOTE: Spent adsorption media will not be regenerated and used.
If adsorption media is affected by chlorine, water supply should be
treated to remove chlorine prior to entering filter.
EVERPURE