1. GB - Product information
EXHAUSTO CDT control EFC18 is, like the EXHAUSTO CDT chimney fan, designed to be
used with fire places, stoves and boilers for solid fuel.
Using the temperature sensor, the control unit can stop and start the chimney fan automati-
cally. Simple programming allows the EFC18 to be used with either an open fire, a stove or
boiler.
If more fuel needs to be added whilst the fire is burning the fan speed can be increased to
full for 3 minutes by a single press on the ON/OFF button.
The fan voltage and speed has an adjustment between 1 and 9.
1.1 Fitting the EFC18 and temperature sensor
Fitting the EFC18
• To separate the panel, first remove
the frame.
• There are two screws at the back
of the frame which hold the panel in
place on the base. Loosen these and
take off the panel.
• Fit the base on a wall.
Fitting the temperature sensor
RSV
• Fit the sensor to the base plate of the
chimney fan.
• The sensor should be positioned.
See picture below