3.1
System control
The control is determined by a float switch installed in the tank.
3.2
Float valve
Operating temperature
Operating pressure
Flow rate max.
Connections
3.3
3 way switch-over valve
Voltage / Frequency
Output
Flow rate max.
Opening time
Close time
Pressure max.
Allowable pressure differen-
tial
3.4
Pressure and flow rate sensor „Brio"
Voltage / Frequency
Nominal current
Start-up pressure
(factory setting)
Start-up pressure adjustable
between
Operating pressure max.
Volume flow rate max.
Protection classification
Restarting after dry running the pump is possible by means of the "RESET" button.
If there is a water pressure hammering in the system due to the rapid closing of valves (e.g. solenoid valve
in the high pressure cleaner) then please contact the GRAF Company.
3.5
Pump
Drive unit
3.5.1 Mains water back-up supply
Power consumption
Pump head height max.
Pressure max.
Pump discharge rate max.
Suction height max.
Suction length max.
Concerning suction height as a function of the suction length see also diagram 1.
info@garantia.com
www.garantia.com
3.
Technical data
30°C max.
0.3 – 4.5 bar (if there is too strong water pressure a pressure reducer
must be installed!)
1.7 m
3
/h
3
/
OUTSIDE THREAD
4
230 V / 50 Hz
6 W (bei Ventilbewegung)
16 m
3
/h
ca. 10 sek
ca. 5 sek
10 bar
0.7 bar
230 V / 50/ 60 Hz
12 A
1.2 bar
1 – 3.5 bar
10 bar
80 l/min
IP 65
Single phase AC motor 220 – 240 V / 50 Hz with integrated overload pro-
tection IP 44, isolation class F.
660 W
35 m
3.5 bar
3600 l/h (see also diagram 2)
6 m
15 m
18 / 28