Halfen FPA
Installing the bottom cast-in support in the precast panel
Angle bracket
1
Polystyrene
recess former
2
2
On-site reinforcement
3
3
4
The bottom cast in support FPA-3/5-E consists of an U-bracket,
an angle bracket and a polystyrene recess former, delivered
preassembled.
U-bracket
Insert the reinforcing stirrups, through the provided holes,
dimensions according to the table.
Bottom cast in support - additional reinforcement dimensions [mm]
Load range
d
,
s
E
e
l
E
Ø i
E
Fix the cast-in support with nails to the formwork. Nail holes are pro-
vided in both, the U-shaped bracket and in the angle bracket.
Note: Auxilliary construction must be flush
with the ① angle bracket surface!
→ upper concrete edge = lower edge of auxilliary construction
Wooden auxilliary
construction
Upper concrete edge
l
E
d
,
s
E
60°
for load range 34,0 to 56,0
e
5,0
8,0
11,5
16,0
6
6
8
250
250
250
350
24
24
32
32
Upper concrete edge
© 2024 Leviat · INST Halfen FPA 09/15 · www.leviat.com
Assembly Instructions
Ø i
E
22,0
34,0
46,0
8
8
10
12
25
42
400
500
500
32
40
48
56,0
12
52
600
48