2.4.3 Activating/deactivating the "Cooling" mode
Information: "Cooling" function
• Activating the "Cooling" mode allows the machine's cycle to be automatically reversed to cool the pool
water.
• When the "Cooling" function is activated, as soon as the water temperature exceeds the setpoint
temperature by more than 2°C (see following diagram), the heat pump automatically activates the
"Cooling" function until the temperature setpoint is reached (+ 0.5°C).
• When the "Cooling" function is activated (+2°C above the setpoint temperature), the heat pump will
automatically switch to "Cooling" mode (LED strip lit in blue, see § "2.2.2 LED strip") until returning to the
setpoint temperature (+ 0.5°C).
30°C
28,5°C
28°C
27,5°C
• From the main screen (where the measured water temperature is displayed), press and hold
displayed on the screen.
• Press and release
"On" (= activated) or "Off" (= deactivated). If necessary, press and release
("On" or "Off") that is required.
• When the "Cooling" function is activated, the LED strip flashes blue 3 times.
• Once the "Cooling" function is activated or deactivated, press
(where the measured water temperature is displayed).
18
Heating
Heating
(Green LED)
(Green LED)
, depending on the "Cooling" function status (activated or deactivated), the screen displays
Temperature setpoint
Triggering threshold for the
"Heating" function
Triggering threshold for the
"Cooling" function
Cancellation threshold for
the "Heating" and "Cooling
Cooling
(Blue LED)
or
to switch to the status
several times to return to the main screen
functions
. "COOL" is