Télécharger Imprimer la page

Flotec FP7105-08 Notice D'utilisation page 3

Publicité

Les langues disponibles

Les langues disponibles

Installation
Air Valve
Protective
Cap
Air Valve
Figure 1 - Air valve and protective cap.
Tank Precharge Settings for use with
PENTEK INTELLIDRIVE™ Variable
Frequency Drives
Set the pressure tank's pre-charge to 70 percent of the
system operating pressure. When using an external set
point as well as an internal set point, pre-charge the
tank to 70 percent of the lower set point of the two.
Some applications may require a different percentage
when figuring the set point. Refer to your PENTEK
INTELLIDRIVE™ operator's manual for additional
information.
Product Information – Pre-Charged Tanks
Model Number
Maximum
Capacity
US Gals (L)
FP7105-08
2 (7.6)
FP7107
5 (18.9)
For parts or assistance, call Flotec Customer Service at 800-365-6832
Equivalent to
Drawdown - US.Gals (L)
Standard Tank
20-40 PSI
US Gals (L)
(138-276kPa)
6 (23)
0.7 (2.6)
15 (56.8)
1.8 (6.8)
Standard Tank Replacement
When replacing a standard tank in a water system with
a pre-charged tank, no bleeder orifices or Air Volume
Control (AVC) are required. When sizing a pre-charged
tank to replace a standard tank, the tanks should have
equivalent drawdowns.
Hazardous voltage and hazardous pressure.
Can shock, burn or kill. Disconnect all power to pump
and bleed all pressure from system before working on
pump, tank, or piping.
30-50 PSI
40-60 PSI
(207-345kPa)
(276-414kPa)
0.6 (2.3)
0.5 (1.9)
1.5 (5.7)
1.3 (4.9)
Tank Diameter
Tank Height
in. (mm)
in. (mm)
8-3/8" (213)
12-9/16" (319)
10.6" (269)
16.2" (411)
3
Tank Discharge
Tapping
3/4"
3/4"

Publicité

loading

Ce manuel est également adapté pour:

Fp7107